Asbestos Abatement Guidelines and Policies <br />Page 01563-3 <br /> <br /> d. Workers from the building exterior enter the clean room then the holding <br />area to remove decontaminated equipment and/or containers for <br />disposal. Require these workers to wear full protective clothing and <br />respiratory protection as described in Section 01562. <br /> <br />C. Decontamination Unit Contamination: <br /> <br /> 1. If the air quality in the decontamination unit exceeds 0.01 fibers per cubic <br />centimeter analyzed by PCM or its integrity is diminished through use as <br />determined by the designer or industrial hygiene firm, no employee shall use <br />the unit until corrective steps are taken and approved by the designer and <br />industrial hygiene firm. <br />DocuSign Envelope ID: 09980A3B-0691-41B4-854D-3865F2287392