Browse
Search
2021-289-AMS-CT Wilson construction-Orange County Renovations
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2021
>
2021-289-AMS-CT Wilson construction-Orange County Renovations
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2021 3:18:56 PM
Creation date
7/2/2021 3:06:31 PM
Metadata
Fields
Template:
Contract
Date
5/19/2021
Contract Starting Date
5/19/2021
Contract Ending Date
5/31/2021
Contract Document Type
Contract
Amount
$740,844.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
921
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Construction Documents <br />20052.02 / Orange County - Justice <br />Facility <br />28 4600 - 1 FIRE DETECTION AND ALARM <br />SECTION 28 4600 <br />FIRE DETECTION AND ALARM <br />PART 1 GENERAL <br />1.01 SECTION INCLUDES <br />A.Fire alarm system design and installation, including all components, wiring, and conduit. <br />B.Replacement and removal of existing fire alarm system components, wiring, and conduit <br />indicated. <br />1.02 REFERENCE STANDARDS <br />A.NFPA 70 - National Electrical Code; National Fire Protection Association, Including All <br />Applicable Amendments and Supplements; 2017. <br />B.NFPA 72 - National Fire Alarm and Signaling Code; 2013 <br />C.NFPA 101 - Life Safety Code; Most Recent Edition Adopted by Authority Having Jurisdiction, <br />Including All Applicable Amendments and Supplements. <br />1.03 SCOPE <br />A.Remove and reinstall existing fire alarm devices for existing fire alarm system and verify system <br />complete and fully functional. Contractor shall provide all parts and pieces required to achieve a <br />fully functional system. <br />1.04 SUBMITTALS <br />A.Proposal Documents: Submit the following with cost/time proposal: <br />1.NFPA 72 "Record of Completion", filled out to the extent known at the time. <br />2.Manufacturer's detailed data sheet for each control unit, initiating device, and notification <br />appliance. <br />3.Certification by Contractor that the system design will comply with the contract documents. <br />B.Drawings must be prepared using the latest release of ACAD. <br />C.Evidence of designer qualifications. <br />D.Design Documents: Submit all information required for plan review and permitting by authorities <br />having jurisdiction, including but not limited to floor plans, riser diagrams, and description of <br />operation: <br />1.NFPA 72 "Record of Completion", filled out to the extent known at the time. <br />2.Clear and concise description of operation, with input/output matrix similar to that shown in <br />NFPA 72 Appendix A-7-5-2.2(9), and complete listing of software required. <br />3. System zone boundaries and interfaces to fire safety systems. <br />4. Location of all components, circuits, and raceways; mark components with identifiers used <br />in control unit programming. <br />5. Circuit layouts; number, size, and type of raceways and conductors; conduit fill <br />calculations; spare capacity calculations; notification appliance circuit voltage drop <br />calculations. <br />6. System response matrix. <br />7. System riser diagram <br />8. Battery calculations showing voltage drop after required standby time. <br />9. List of all devices on each signaling line circuit, with spare capacity indicated. <br />10. Manufacturer's detailed data sheet for each component, including wiring diagrams, <br />installation instructions, and circuit length limitations. <br />11. Description of power supplies; if secondary power is by battery include calculations <br />demonstrating adequate battery power. <br />12. Certification by either the manufacturer of the control unit or by the manufacturer of each <br />other component that the components are compatible with the control unit. <br />13. Certification by the manufacturer of the control unit that the system design complies with <br />the contract documents. <br />14. Certification by Contractor that the system design complies with the contract documents. <br />DocuSign Envelope ID: 09980A3B-0691-41B4-854D-3865F2287392
The URL can be used to link to this page
Your browser does not support the video tag.