Orange County NC Website
Construction Documents <br />20052.02 / Orange County - Justice <br />Facility <br />26 0553 - 1 IDENTIFICATION FOR ELECTRICAL <br />SYSTEMS <br />SECTION 26 0553 <br />IDENTIFICATION FOR ELECTRICAL SYSTEMS <br />PART 1 GENERAL <br />1.01 SECTION INCLUDES <br />A.Electrical identification requirements. <br />B.Identification nameplates and labels. <br />C.Wire and cable markers. <br />D.Underground warning tape. <br />E.Warning signs and labels. <br />1.02 RELATED REQUIREMENTS <br />A.Section 26 0519 - Power Conductors and Cables: Color coding for power conductors and <br />cables 600 V and less; vinyl color coding electrical tape. <br />B.Section 26 0536 - Cable Trays for Electrical Systems: Additional identification requirements for <br />cable tray systems. <br />C.Section 26 2726 - Wiring Devices - Lutron: Device and wallplate finishes; factory pre-marked <br />wallplates. <br />D.Section 27 1000 - Structured Cabling: Identification for communications cabling and devices. <br />1.03 ADMINISTRATIVE REQUIREMENTS <br />A.Coordination: <br />1.Verify final designations for equipment, systems, and components to be identified prior to <br />fabrication of identification products. <br />B.Sequencing: <br />1.Do not conceal items to be identified, in locations such as above suspended ceilings, until <br />identification products have been installed. <br />2.Do not install identification products until final surface finishes and painting are complete. <br />1.04 SUBMITTALS <br />A.Product Data: Provide manufacturer's standard catalog pages and data sheets for each <br />product. <br />B.Shop Drawings: Provide schedule of items to be identified indicating proposed designations, <br />materials, legends, and formats. <br />1.05 FIELD CONDITIONS <br />A.Do not install adhesive products when ambient temperature is lower than recommended by <br />manufacturer. <br />PART 2 PRODUCTS <br />2.01 IDENTIFICATION REQUIREMENTS <br />A.Identification for Equipment: <br />1.Use identification nameplate to identify each piece of electrical distribution and control <br />equipment and associated sections, compartments, and components. <br />a.Switchboards: <br />1)Identify ampere rating. <br />2)Identify voltage and phase. <br />3)Identify power source and circuit number. Include location. <br />4)Use identification nameplate to identify main overcurrent protective device. <br />5)Use identification nameplate to identify load(s) served for each branch device <br />where not identified in a panelboard schedule. <br />b.Panelboards: <br />1)Identify ampere rating. <br />DocuSign Envelope ID: 09980A3B-0691-41B4-854D-3865F2287392