Fields
Template:
Contract
Date
5/19/2021
Contract Starting Date
5/19/2021
Contract Ending Date
5/31/2021
Contract Document Type
Contract
Amount
$740,844.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
921
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Orange County Facility Renovations <br />Hillsborough, NC <br /> <br /> <br /> <br />Smith Sinnett ACOUSTICAL PANEL CEILINGS <br />2020046/2020047/2020048/2020049/2020055 09 51 13 - 4 <br />3. Splay hangers only where required and, if permitted with fire-resistance-rated ceilings, to miss <br />obstructions; offset resulting horizontal forces by bracing, counters playing, or other equally <br />effective means. <br />4. Where width of ducts and other construction within ceiling plenum produces hanger spacings that <br />interfere with location of hangers at spacings required to support standard suspension system <br />members, install supplemental suspension members and hangers in form of trapezes or equivalent <br />devices. <br />5. Secure wire hangers to ceiling suspension members and to supports above with a minimum of <br />three tight turns. Connect hangers directly either to structures or to inserts, eye screws, or other <br />devices that are secure and appropriate for substrate and that will not deteriorate or otherwise fail <br />due to age, corrosion, or elevated temperatures. <br />6. Do not support ceilings directly from permanent metal forms or floor deck. Fasten hangers to <br />cast-in-place hanger inserts, post installed mechanical or adhesive anchors, or power-actuated <br />fasteners that extend through forms into concrete. <br />7. When steel framing does not permit installation of hanger wires at spacing required, install <br />carrying channels or other supplemental support for attachment of hanger wires. <br />8. Do not attach hangers to steel deck tabs. <br />9. Do not attach hangers to steel roof deck. Attach hangers to structural members. <br />10. Space hangers not more than 48 inches o.c. along each member supported directly from hangers, <br />unless otherwise indicated; provide hangers not more than 8 inches from ends of each member. <br />11. Size supplemental suspension members and hangers to support ceiling loads within performance <br />limits established by referenced standards and publications. <br />C. Secure bracing wires to ceiling suspension members and to supports with a minimum of four tight turns. <br />Suspend bracing from building's structural members as required for hangers, without attaching to <br />permanent metal forms, steel deck, or steel deck tabs. Fasten bracing wires into concrete with cast-in- <br />place or post installed anchors. <br />D. Install edge moldings and trim of type indicated at perimeter of acoustical tile ceiling area and where <br />necessary to conceal edges of acoustical tiles. <br />1. Apply acoustical sealant in a continuous ribbon concealed on back of vertical legs of moldings <br />before they are installed. <br />2. Screw attach moldings to substrate at intervals not more than 16 inches o.c. and not more than 3 <br />inches from ends, leveling with ceiling suspension system to a tolerance of 1/8 inch in 12 feet. <br />Miter corners accurately and connect securely. <br />3. Do not use exposed fasteners, including pop rivets, on moldings and trim. <br />E. Install suspension system runners so they are square and securely interlocked with one another. Remove <br />and replace dented, bent, or kinked members. <br />F. Arrange directionally patterned acoustical tiles as follows: <br />1. Install tiles with pattern running in one direction parallel to long axis of space. <br />END OF SECTION <br /> <br />DocuSign Envelope ID: 09980A3B-0691-41B4-854D-3865F2287392