Browse
Search
2021-289-AMS-CT Wilson construction-Orange County Renovations
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2021
>
2021-289-AMS-CT Wilson construction-Orange County Renovations
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2021 3:18:56 PM
Creation date
7/2/2021 3:06:31 PM
Metadata
Fields
Template:
Contract
Date
5/19/2021
Contract Starting Date
5/19/2021
Contract Ending Date
5/31/2021
Contract Document Type
Contract
Amount
$740,844.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
921
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Orange County Facility Renovations <br />Hillsborough, NC <br />Smith Sinnett PENETRATION FIRESTOPPING <br />2020046/2020047/2020048/2020049/2020055 07 84 13 - 1 <br />SECTION 07 84 13 - PENETRATION FIRESTOPPING <br />PART 1 - GENERAL <br />1.1 SUMMARY <br />A. Section Includes: <br />1. Penetration firestopping systems for the following applications: <br />a. Penetrations in fire-resistance-rated walls. <br />1.2 PREINSTALLATION MEETINGS <br />A. Preinstallation Conference: Conduct conference at Project site. <br />1.3 ACTION SUBMITTALS <br />A. Product Data: For each type of product. <br />B. Product Schedule: For each penetration firestopping system. Include location, illustration of firestopping <br />system, and design designation of qualified testing and inspecting agency. <br />1. Engineering Judgments: Where Project conditions require modification to a qualified testing and <br />inspecting agency's illustration for a particular penetration firestopping system, submit illustration, <br />with modifications marked, approved by penetration firestopping system manufacturer's fire- <br />protection engineer as an engineering judgment or equivalent fire-resistance-rated assembly. <br />Obtain approval of authorities having jurisdiction prior to submittal. <br />1.4 INFORMATIONAL SUBMITTALS <br />A. Product test reports. <br />1.5 CLOSEOUT SUBMITTALS <br />A. Installer Certificates: From Installer indicating that penetration firestopping systems have been installed <br />in compliance with requirements and manufacturer's written instructions. <br />1.6 QUALITY ASSURANCE <br />A. Installer Qualifications: A firm that has been approved by FM Approval according to FM Approval 4991, <br />"Approval of Firestop Contractors," or been evaluated by UL and found to comply with its "Qualified <br />Firestop Contractor Program Requirements." <br />DocuSign Envelope ID: 09980A3B-0691-41B4-854D-3865F2287392
The URL can be used to link to this page
Your browser does not support the video tag.