Orange County NC Website
83 <br /> Shell vs . Tenant Improvement <br /> Worksheet <br /> Note: This tool shall serve as helpful guidance when checking construction bids. <br /> For further guidance,check the Pricing Desk Guide: Fourth Edition, Sections 2.4 and 2.5 <br /> Item Include in Include in <br /> Number Bid Item Shell Rate TI Allowance <br /> 1 Accessibility Requirements (ABAAS) X <br /> Base Building — Complete base structure and building X <br /> 2 enclosure <br /> 3 Ceiling -Above standard X <br /> 4 Ceiling—Acoustical w/grid and lay in tiles X <br /> Corridors - Circulation on multi-tenanted floors, fire egress on X <br /> 5 singe-tenanted floors <br /> 6 Data --Conduit drops with pull string, cable trays X <br /> 7 Demolition X <br /> Doors - Additional exterior requested by government (unless X <br /> 8 required for fire/life safety) <br /> 9 Doors- Sidelights and frames X <br /> Doors - Standard exterior, doors to lobbies, common areas, X <br /> 10 and core areas, including hardware and signage <br /> Doors - Suite entry or interior doors within tenant area, X <br /> 11 including hardware and signage <br /> 12 Drawings-As-built floor plans X <br /> 13 Drawings- Construction Documents X <br /> 14 Drawings- Design Intent Drawings X <br /> 15 Drinking Fountains per RLP/Lease Standards X <br /> 16 Electrical —Furniture whip hook up X <br /> Electrical - Main distribution for standard occupancy, X <br /> 17 Iswitchboards, and panel boards (circuit breaker) <br /> 18 Electrical—Supplemental power X <br /> Electrical —Wiring and horizontal conduit including cable trays <br /> and hooks within the tenant agency's demised premises and X <br /> 19 to building core <br /> Electrical Outlets - All electrical, telephone, and data within X <br /> 20 government-demised area <br /> Electrical Outlets - Convenience and duplex utility in toilet X <br /> 21 rooms, corridors, and dispensing areas <br /> 22 Elevators- Private, within tenant space X <br /> 23 Elevators- Freight, when required by agency in RLP/Lease X <br /> 24 Exits and access- Permanent entryway systems X <br /> 25 Fire Alarm - Building central system (as required by code) X <br /> Fire Alarm — Wiring from building core to tenant agency <br /> space and then within tenant agency space; pull stations, X <br /> 26 strobes, and annunciators within the demised premises <br /> 27 Flagpole X <br /> 28 Flooring - Carpet or resilient flooring (demised area only) X <br /> 29 Flooring - Raised access flooring X <br /> Flush-out procedure - New air filtration media before X <br /> 30 occupancy <br /> Page 2 OF 4 <br /> INITIALS: LESSOR: &GOVT: <br />