heating all habitable rooms , bathrooms , and water closet compartments to a minimum <br /> temperature of 68 degrees Fahrenheit measured three feet above the center of the floor <br /> whenever the outdoor temperature is below 55 degrees Fahrenheit . <br /> ( b) If a dwelling unit contains a heating system or heating appliances that meet the requirements of <br /> subsection ( a) of this section , the owner of the dwelling unit shall not be required to install a new <br /> heating system or heating appliances , but the owner shall maintain the existing heating system or <br /> heating appliances in a good and safe working condition . Otherwise , the owner of the dwelling <br /> unit shall install a heating system or heating appliances that meet the requirements of subsection <br /> ( a ) of this section and shall maintain the heating system or heating appliances in a good and safe <br /> working condition . <br /> (c) Portable kerosene heaters are not acceptable as a permanent source of heat as required by <br /> subsection ( a) of this section but may be used as a supplementary source in single -family <br /> dwellings and duplex units . An owner who has complied with subsection (a) of this section shall <br /> not be held in violation of this section where an occupant of a dwelling unit uses a kerosene <br /> heater as a primary source of heat . <br /> {-a-) ( d ) Nothing in this section shall be construed to diminish the rights or remedies available to a <br /> tenant under a lease agreement , statute , or at common law . <br /> (Ord . of 2 -214984 , art . 6 , eff. 744984) <br /> Sec . 20-37 . - Minimum standards for electrical equipment and facilities . <br /> Every dwelling and dwelling unit shall be wired for electrical lights and convenience receptacles as <br /> follows : <br /> ( a) Every habitable room containing 70 square feet oft floor area or less shall contain at least two <br /> floor or wall -type electrical convenience receptacles and every habitable room containing more <br /> than 70 square feet of floor area shall be provided with at least three receptacles but not less than <br /> one receptacle for every 50 square feet of floor space . <br /> ( b ) Every bathroom , water closet room , laundry room , and furnace room shall contain at least one <br /> supplied ceiling or wall type electric light fixture . <br /> (c) Every public hall and stairway in every multiple dwelling shall be adequately lighted by electrical <br /> lights from sunset to sunrise . <br /> ( d ) All electrical fixtures , receptacles , equipment and wiring shall be maintained in a state of good <br /> repair, safe , free of fire or shocking hazards , and capable of performing the function for which it <br /> was originally intended . <br /> (e) Whenever all or any part of the existing electrical system , wiring , or fixtures shall be replaced , <br /> modified , altered , or expanded then such new installation shall be made in accordance with the <br /> North Carolina State Building Code . <br /> ( Ord . of 2 -214984 , art . 7 , eff. 744984) <br /> Sec . 20-38 . - Minimum standards for lighting and ventilation . <br /> ( a) Every dwelling unit shall be provided with natural light and ventilation by one or more windows , <br /> opening to the outdoors , as follows : <br /> ( 1 ) In dwelling units containing fewer than five habitable rooms exclusive of kitchens , bathrooms ; <br /> and water closets , a window or windows shall be provided in all habitable rooms . <br /> (2) In dwelling units containing five or more habitable rooms exclusive of kitchens , bathrooms and <br /> water closets , a window or windows shall be provided in at least four habitable rooms . <br />