Orange County NC Website
DocuSign Envelope ID:81 E05E8E-EED7-43D3-8B8A-0811 OE72140A <br /> Initial System Specifications: <br /> Line Color Layout Needed <br /> Length Length <br /> 1 White 64' 55' <br /> 2 Blue 65' 55' <br /> 3 Orange 66' 57' <br /> Total: 195' 167' <br /> Dosing Volume: <br /> 66—75% of pipe volume <br /> 167' of pipe x 65.3 gal/100' = 109 gallons <br /> 66%: 109 x.66 = 73 gallons <br /> 75%: 109 x.75 = 82 gallons <br /> Pressure Manifold Tap Requirements: <br /> Line Tap Dia. Tap Sch. Tap Flow' Line Length Flow/Foot <br /> 1 %" 80 10.1 55' .18 <br /> 2 %" 80 10.1 55' .18 <br /> 3 %" 80 10.1 57' .18 <br /> Total: 30.3 167' <br /> 1. Tap Flows @ 2' Pressure Head <br /> 2. Pump shall be sized to deliver 33 gpm @ TDH determined by pump and manifold <br /> elevation and location and allows for vent hole flow loss. <br /> Notes: <br /> 1. Septic system is to serve only the employees (4) of the facility <br /> 2. No public restrooms <br /> 3. Facility Hours of Operation: <br /> a. Monday,Tuesday,Thursday, Friday 7 am—6 pm <br /> b. Saturday 7 am—5 pm <br /> c. Sunday 1 pm—6 pm <br /> d. Wednesday closed <br /> 4. Domestic wastewater only <br /> 5. The septic field is remote to the facility location. <br /> 6. Soil series: Herndon <br /> 7. A thin layer of red clay fill was found to be existing over the usable soil area with 3-17" <br /> at varying depths <br /> 8. Soil area lies in cow pasture adjacent to Freeland property <br /> 9. Recommend fencing off drainfield area from livestock <br /> 10. System is to replace current Pump and Haul system used at facility <br /> 11. Existing well serves as water supply for facility <br /> Project# 320059 <br />