Browse
Search
2021-205-E-Solid Waste-Full Circle Environmental-Walnut Grove Wastewater Disposal System
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2021
>
2021-205-E-Solid Waste-Full Circle Environmental-Walnut Grove Wastewater Disposal System
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/17/2021 2:50:16 PM
Creation date
5/17/2021 2:38:57 PM
Metadata
Fields
Template:
Contract
Date
4/26/2021
Contract Starting Date
4/26/2021
Contract Ending Date
4/26/2021
Contract Document Type
Contract
Amount
$29,130.00
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID:81 E05E8E-EED7-43D3-8B8A-0811 OE72140A <br /> SL 2018-114 (0 Conditions and Site Features: <br /> The information below is provided to facilitate the IP/CA issuance. The water supply is <br /> proposed to use the existing well. One additional feature I would recommend is to <br /> construct protective fencing around the soil area and septic layout. The perimeter of <br /> the septic layout is marked with double wire flags denoting septic lines. Due to the <br /> limited area of usable soil and layout, there is no room for error if a portion of the of the <br /> field or repair is destroyed during construction. No grading, filling, storage, compaction <br /> or disturbance should be allowed over the soil/septic area. <br /> 3 605 Walnut Grove Church Road <br /> PIN: 9867419070— 18.13 Acres <br /> Design Flow: 4 employees x 25 gpd/employee= 100 gpd <br /> LTAR: .2 gpd/ff <br /> Trench Bottom Square Footage Required: 100 gpd/.2 gpd/ftz= 500 ftz <br /> Drainfleld Requirement: 500 ft2/3 ft trench= 167 ft. <br /> System and Repair Requirement: <br /> Conventional trench: 334' (167'+ 167') <br /> Usable Soil Depth (Initial): 38" (Based on borings A, B and D in usable soil area) <br /> System Type: Conventional Trench for initial with pump delivery. (Illb) <br /> Usable Soil Depth (Repair): 28" (Based on borings B, C, E and F in usable soil area) <br /> System Type: Conventional Trench for repair with imported soil cap and pump delivery. (Illbu) <br /> System Distribution: Initial system with Pressure Manifold. <br /> Septic Layout: <br /> Line Color Length' Elev. Initial Repair <br /> 1 White 64' 511111 64' <br /> 2 Blue 65' 61411 65' <br /> 3 Orange 66' 6' 8.5" 66' <br /> 4 Purple 68' 7' 1.5" 68' <br /> 5 Lime 71' 711111 71' <br /> 6 White 72' 8' 5.5" 72' <br /> Total: 406' 195, 211' <br /> 1. Amount of line length meets available space requirements (.1945) <br /> 2. Lines laid out 9' on center at minimum <br /> 3. Benchmark Elevation: Top of EIP @ property corner adjacent to layout: 5'4" <br /> 4. Line lengths measured with Rolatape measuring wheel <br /> 5. Line ends are double flagged. <br /> 6. Usable soil depths are slope corrected. <br /> Project# 320059 <br />
The URL can be used to link to this page
Your browser does not support the video tag.