<br /> GENERAL NOTES
<br /> 1. COORDINATE EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF ALL HVAC AND
<br /> PLUMBING EQUIPMENT WITH RESPECTIVE CONTRACTORS. NOTIFY ENGINEER
<br /> IMMEDIATELY, IN WRITING,OF ANY DISCREPANCIES.
<br /> Y 2. ALL ELECTRICAL DEVICES IN SHOP AREA 170 SHALL BE SURFACE MOUNTED.
<br /> 3, ALL CIRCUITS ON THIS SHEET FROM PANEL WITH"POB"PREFIX.
<br /> I
<br /> I I I I
<br /> ARCHITECTURE
<br /> 1100 Dresser Court
<br /> I P1-7,9 i 1 I Raleigh, NC 27609
<br /> HAND DRYER P1-49 KEY NOTES T® E101 Office 919.828.2301
<br /> ---
<br /> ----- --- Email office@hh-arch.com
<br /> �J ,i
<br /> 2 4 =POB-UH-2 P1-9 P1-3 P1 PlI*I 5,,t,, 1 (2)4"TELECOM SERVICE CONDUITS FROM SITE PLAN,STUBBED UP TO 6"ABOVE FLOOR.
<br /> Ll
<br /> Pi-50 I I___11 P1-15 I i ° 14POB- P-1
<br /> 1i113oa�i � GFI FFI 2 PROVIDE RECEPTACLE CORD REEL ATTACHED TO BUILDING STRUCTURE. SEE DETAIL SHEET.
<br /> 14 POB-E -9 SHOWERPl- ` i �' �1-5 Pi-13 = - _ --_--_
<br /> i60G_ 1-3 I M17-17,19
<br /> ra07 2 PI-4 j WP 3 ELECTRIC WATER COOLER. REFER TO DETAIL 4/E201
<br /> i
<br /> P1 3 P1-15 P1-45
<br /> 14 POB-EXH idti= - P1-5 I M1-1
<br /> P1-1 PARKS t4 5 GROUND BUS PER PROJECT DETAILS
<br /> M1-13 "' TOILET Pi-1 P1-13 5 Pi-13 DR - POB-EXH-8
<br /> -M1-1 160F LO BY i v 1608 6 INSTALL FIRE RATED PLYWOOD ON WALL TO 8'-0"AFF AND PAINT TO MATCH WALL COLOR.
<br /> ® M_i b�� 1�J ��
<br /> i4 ROB-lIH-3 HAN RYER - 3 `i 0 OB-HP-2
<br /> Pi-7 i -- —
<br /> �FI M1-1 � � P1-47 • • P -13 14 7 WALL MOUNTED 66 BOCKS FOR DEDICATED PHONE LINE DISTRIBUTION.
<br /> PI-3 Pi- 4 I I '` _ - - - - - - -
<br /> PO H�1 �RIIVK. 1-15 0II wH CUST STOR. !Pi-13,15,17 P1-15 M1-2i,23- - -
<br /> 6fl 1 I6QC 8 WALL MOUNTED GROUND BUS SIMILAR TO PROJECT DETAILS.
<br /> M1-2, MISER P ° iia
<br /> 14 -
<br /> 4`6 -- - - -- - - -
<br /> ���-- — s = _ ? g s 9 REFER TO POWER RISER ON ELECTRICAL DISTRIBUTION SHEET FOR DESCRIPTION.
<br /> — —
<br /> M�2, — y —
<br /> EI"_- 8
<br /> P1-10 �- R P�-26 1.2 Pl 6 I 11 PROVIDE WP SBOX AT BOTTOM OF ROOF STRUCTURE WITH 1"C TO PANEL P1 FOR FUTURE LIFT.
<br /> P1-4 �,` U
<br /> P -24,26 E 01 L
<br /> ® P1-2,4,6 12 PROVIDE DISCONNECT AT OVERHEAD DOOR OPERATOR AND MAKE POWER CONNECTION.
<br /> �' PROVIDE EMPTY 1/2"EMT FOR DOOR CONTROL SWITCH AS DIRECTED BY DOOR INSTALLER.FUSE
<br /> 38 42
<br /> P1- ,40, I r I PUN.
<br /> 0 i 13 TELECOM WALL ENCLOSURE W W
<br /> "
<br /> 14 CONNECT CIRCUIT FOR MECHANICAL EQUIPMENT TO DISCONNECT PROVIDED BY MECHANICAL
<br /> " CONTRACTOR.
<br /> - - POB-EXH-3 _ \`\ _ /i��- ® P1-32,34,36 A/
<br /> ii �!� - - POB-F-7� - - 7i���'� - = P1-31 15 PROVIDE 1"CONDUIT AND PULL STRING TO WEATHERPROOF J-BOX AT BOTTOM OF ROOF lia
<br /> " a M1-11C / ,\� O�B-F-6 �!y \ b WP STRUCTURE FOR FUTURE LIFT.
<br /> �1� — P1-10 Pi 10 _ a O _ �� ® ,30 ® "I —,✓ J 30_A G -6 — rj
<br /> 54" WP- P {LJ M1-28, - P1-6• 54" 2 16 PROVIDE 1"CONDUIT BACK TO IT CLOSET IN STORAGE ROOM 160C.
<br /> 54„ - =-29- --� - Z Z
<br /> I M1 32,34 I 54'i
<br /> 30 A P1-29,31 11110
<br /> 17 PROVIDE POWER CONNECTION TO LINE SIDE OF DISCONNECT SERVING DOMESTIC WATER HOT 0
<br /> P1,38,40,42 �
<br /> _ " BOX
<br /> POB-EXH-2 "
<br /> "
<br /> i a M1-9 ALL SWITCHES, RECEPTACLES AND JUNCTION BOXES I U
<br /> IN THIS AREA SHALL BE MOUNTED AT+42"ABOVE I- I = z
<br /> FINISHED FL OR UNLESS OTHERWISE NOTED.ALL I P1-32V
<br /> CONDUITS S ALL BE ROUTED OVERHEAD.ANY I M1-1 35 O W
<br /> CONDUIT EN EKING THE AREA CONSISTING OF+18'° - _ I_ _ ._ _
<br /> s i
<br /> FJNI OR TO THE BOT3=0M OF TFIE — J — - �43A- — — �
<br /> ,54° ® GROUND FLOOR SLAB SHALL BE IN RIGID METAL j POB HV-1 P1,5 W O O
<br /> i - - ® °� CONDUIT AND SHALL HAVE A SEAL OFF"EYS"FITTING ,, , 0
<br /> P1-13 i MI-7 ED WHERE CON UIT ENTERS AND LEAVES THE AREA. ® J i (!j Ce
<br /> P1-3 P1-30 P1-13 ` - - i P1-33 P1-35 Z W O
<br /> POB-EXH-1 (�
<br /> 1-25 27�� 1 � 13 " " /�/ un
<br /> L _ _ J P1-37 14Pi-19 P1-28 P1-28,30 ; I "
<br /> - - - P1-33,35
<br /> � 570 M1-7,9,11
<br /> " U H-1 W 2 14 y 6 7 8 1 " rii �� �ii O S ) P1-38 40 42 ` 30
<br /> " y " 00® _ °� WP P1-8,10,12 _ _ _ _ M1-20 22 B-F- = - \�-
<br /> P1-10 � 30'A I GFIPO I "i a� 1 3, _ E ® — ® � — _ Pi-32 34 36
<br /> — — — — — Stanford
<br /> rpl_12 14 a M1-8 M1-24,2600
<br /> 3 � J POB-IRH-1 - R n � P1-6 1f Y �'te
<br /> 2 FIRST FLOOR PLAN -TELECOM E101 —.�. �; „ FIL�Lj
<br /> E101 SCALE; 1/4" = V-0" M1-10- " I - P
<br /> - ; ; ;; ,Ply 4,16,18 M1-12 I - 1620 Midtown Place
<br /> E E o I i POB-IRH-2 1 1l POB-IRH-3 j Raleigh,se -179
<br /> - L �-FT _
<br /> NC License C-1719
<br /> _ J
<br /> P1-16 P1-16 P1-20 fax 919.832 81 0
<br /> - - — — — stanfordwhite.coin
<br /> LMr -------- --------- ----- ---n-------- n -22
<br /> u I Ii it
<br /> I Ii II - lll P WALL RATING LEGEND '�``',1t0 ft
<br /> I P1-22 I .`'`i `'`OS14'•' ma's
<br /> 1-HR RATED FIRE BARRIER
<br /> HEAT TRACE a
<br /> CONNETION ,
<br /> ED
<br /> FACP � RA 8 .' ' tx' �;.•+ i.`'
<br /> PRINTER Pi-12 !f J I I8 I I orfi '. tl1E ���•
<br /> .,,,,..
<br /> FRCP P1-41 ; KEY PLAN
<br /> Lj
<br /> �t
<br /> 16 P01341 POB-PICL
<br /> � 1 HH Addendum 1 7/30/2019
<br /> PV SYSTEM I — i— Pi-14 Pi-2GFI ® Pi, GFI 2 HH Addendum 2 8/6f2019
<br /> POWER OFF 0OB-L1 G — — WP
<br /> DISCONNECT L I _
<br /> POB-MDS
<br /> C 5 P1-112
<br /> POB-PVma ' P1-14 P1-14 I I E-
<br /> - -
<br /> i zLL]L—JP1-22 P1-39 it AC-T I - I
<br /> I m ca GFI GFI o i;
<br /> MOBILE v POB-MTS PV STRING
<br /> GENERATdR m LU INVERTERS WP WP \ JOB NUMBER
<br /> CONNECTII!?N pa a P1-39 ° ,_-' M1-14,16,18
<br /> III L _ _ _ _ _ 15-082
<br /> DATEISSUED
<br /> 1 FIRST FLOOR PLAN - POWER & TELECOMM
<br /> �.
<br /> 07/10/201 9
<br /> SCALE: 1/$" = 1-0"E101 PROJECT STATUS
<br /> N �3 FIRST FLOOR PLAN - ELEC ROOM
<br /> \E1011 SCALE® 1/4" = V-0" 4' 0 4' 8' 12' 16, 20' �° assuEO FOR BID
<br /> SHEET
<br /> 4' 0 4' 8'
<br /> 61
<br /> c FIRST FLOOR
<br /> PLAN - POWER &
<br /> '2o
<br /> TELECOMM
<br /> c ,� an
<br /> d, +� `-'
<br /> � k
<br /> No
<br /> Oz N
<br /> POB
<br /> � o
<br /> .-j E 10 1