Browse
Search
Planning Board - 040721
OrangeCountyNC
>
Advisory Boards and Commissions - Active
>
Orange County Planning Board
>
Agendas
>
2021
>
Planning Board - 040721
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/29/2021 12:15:11 PM
Creation date
3/29/2021 12:06:19 PM
Metadata
Fields
Template:
BOCC
Date
4/7/2021
Meeting Type
Regular Meeting
Document Type
Agenda
Document Relationships
Planning Board minutes - 040721
(Message)
Path:
\Advisory Boards and Commissions - Active\Orange County Planning Board\Minutes\2021
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
353
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Article 5: Uses 202 <br /> Section 5.9: Standards for Utilities <br /> (a) Perimeter fencing and setbacks for the utility structure shall be provided <br /> in accordance with the National Electrical Safety Code. <br /> (b) The facility shall be located on a parcel or an easement across the parcel <br /> (whether owned or leased by the utility)which has been recorded with <br /> the Orange County Register of Deeds. <br /> (c) Access easements extending from an approved public or private road to <br /> the facility shall be a minimum width of 30 feet. <br /> (d) Where a building is involved and it is proposed to be located in a <br /> residentially zoned d+strietarea109, it shall have the appearance suitable <br /> for a residential district, or it shall be screened from adjacent residential <br /> land. <br /> (e) Where buildings are set back from road rights of way or from private <br /> property lines by a distance of 200 feet, screening for the building will not <br /> be required. <br /> (f) A clearly visible voltage warning sign shall be placed at the base of all <br /> pad-mounted transformers and substations. <br /> (g) A Type E Land Use Buffer shall be provided along any portion of the <br /> perimeter of the parcel, easement area, or leasehold area located <br /> adjacent to property zoned or utilized for residential use except where <br /> such property is currently used for electrical distribution or transmission <br /> purposes. <br /> (h) Existing vegetation may be used to satisfy the landscaping requirements. <br /> (i) The applicant shall submit proof of liability insurance covering bodily <br /> injury and property damage demonstrating a minimum coverage limit of <br /> $500,000.00 per occurrence. <br /> (j) The site is of adequate size for the sewage disposal system proposed <br /> and for the proposed use. <br /> 5.9.4 Elevated Water Storage Tanks <br /> (A) Submittal Requirements and Standards of Evaluation for Class n SpeGial Use <br /> PermitConditional Districts <br /> (1) Submittal Requirements <br /> In addition to the information required in Section 2.79, the following shall be <br /> submitted as part of the application: <br /> (a) A site plan showing the following: <br /> 0) Location and size of all existing and proposed structures, <br /> (ii) Existing and proposed topography at a contour interval of five <br /> feet and <br /> (iii) Any officially designated floodways and floodplains, or the <br /> presence of alluvial soils. <br /> (b) Plans and elevations for all proposed structures and descriptions of the <br /> color and nature of all exterior material. <br /> 109 Since Conditional Districts are their own zoning district,this language should be updated since, upon a <br /> Conditional District approval,the property will no longer be considered a residential zoning district,as instituted in <br /> Article 3. <br /> Orange County, North Carolina—Unified Development Ordinance Page 5-70 <br />
The URL can be used to link to this page
Your browser does not support the video tag.