Orange County NC Website
Article 5: Uses 201 <br /> Section 5.9: Standards for Utilities <br /> 5.9.2 Electrical Substations, Switching and Metering Stations, and Associated Transmission <br /> Lines,Where Incoming Voltage Does Not Exceed 100 Kilovolts (kv) <br /> (A) Standards of Evaluation <br /> (1) Perimeter fencing and setbacks for the utility structure shall be provided in <br /> accordance with the National Electrical Safety Code. <br /> (2) The components of the facility, including but not limited to towers, transformers, <br /> circuit breakers, metering devices, and supporting latticework, shall be contained <br /> within a geometric area not to exceed 12,000 square feet. <br /> (3) The facility shall be located on a parcel or easement across the parcel, (whether <br /> owned or leased by the utility)which has been recorded with the Orange County <br /> Register of Deeds. <br /> (4) Access easements extending from an approved public or private road to the <br /> facility shall be a minimum width of 30 feet. <br /> (5) A Type E Land Use Buffer shall be provided along any portion of the perimeter of <br /> the parcel, easement, or leasehold located adjacent to property zoned for <br /> residential use, except where such property is owned, leased or consists of other <br /> utility easements currently used for electrical distribution or transmission <br /> purposes or no other purposes. <br /> (6) Existing vegetation within an easement, leasehold or parcel of a public utility may <br /> be used to satisfy the landscaping requirements. <br /> (7) Modification to or replacement of existing facilities shall be subject to the <br /> requirements set forth in this Section. Pre existing facilities may remain during <br /> construction of replacement facilities, but shall be dismantled after the <br /> replacement facility is in operation. <br /> (8) The parcel or easement across the parcel, (whether owned or leased by the <br /> utility)on which the facility is located shall contain a minimum area of 5000 <br /> square feet. <br /> (9) The applicant shall submit proof of liability insurance covering bodily injury and <br /> property damage demonstrating a minimum coverage limit of$ 500,000.00 per <br /> occurrence. <br /> 5.9.3 Public Utility Stations and Substations,_(Including Electric Substations, Metering, and <br /> Switching Stations Receiving More Than 100 Kilovolts (kv) of Electricityl, Water Treatment <br /> Plant, Sewage Treatment Plant, Telephone Exchanges <br /> (A) Submittal Requirements and Standards of Evaluation for Class a Special Use <br /> Pe�.r::.i*Conditional Districts <br /> (1) Submittal Requirements <br /> In addition to the information required by Section 2.79, the following shall be <br /> submitted as part of the application: <br /> (a) A site plan showing all existing or proposed buildings, storage areas, <br /> parking and access areas, topography at a contour interval of five feet, <br /> any officially designated floodplains or alluvial soils. <br /> (b) Plans and elevations for all proposed structures and descriptions of the <br /> color and nature of all exterior materials. <br /> (c) Landscape Plan, at the same scale as the site plan, showing existing <br /> and proposed trees, shrubs, ground cover and other landscape material. <br /> (2) Standards of Evaluation <br /> Orange County, North Carolina—Unified Development Ordinance Page 5-69 <br />