Browse
Search
Planning Board - 030321 ORC Agenda Packet - Replacement Att 1 - 160D
OrangeCountyNC
>
Advisory Boards and Commissions - Active
>
Orange County Planning Board
>
Ordinance Review Committee
>
Agendas
>
2021
>
Planning Board - 030321 ORC Agenda Packet - Replacement Att 1 - 160D
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2021 3:22:38 PM
Creation date
2/26/2021 2:32:31 PM
Metadata
Fields
Template:
BOCC
Date
3/3/2021
Meeting Type
Regular Meeting
Document Type
Agenda
Document Relationships
Planning Board - 030321 ORC Agenda Packet
(Message)
Path:
\Advisory Boards and Commissions - Active\Orange County Planning Board\Ordinance Review Committee\Agendas\2021
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Article 3: Base Zoning Districts 106 <br /> Section 3.5: Industrial Districts <br /> • . • 1 <br /> Lot Size, min., per use 20,000 <br /> (square feet) <br /> -•• NR[1] 100 <br /> Lot Width, min. (feet) <br /> The purpose of the Medium Industrial-2(1-2)District is to provide AlR—Sly NGRe <br /> locations for enterprises engaged in manufacturing, processing, <br /> creating, repairing, renovating, painting, cleaning, and Front Setback from NR 50 <br /> assembling of goods, merchandise or equipment. Performance ROW, min. (feet) NR GU Neee <br /> standards will be used to insure the absence of adverse impact <br /> beyond the lot boundaries of the use. <br /> Side Setback, min. None[2] <br /> APPLICABILITY (feet) <br /> This district will usually be applied where the following <br /> conditions exist: Rear Setback, min. None [2] <br /> (feet) <br /> 1. Site is located within areas designated by the adopted <br /> Comprehensive Plan as a Commercial-Industrial Transition <br /> Activity Node. Height, max. (feet) 45[3] <br /> 2. Water and sewer mains exist at the site or be made available <br /> as part of the development process. Floor Area Ratio, max. .65 <br /> DIMENSIONAL STANDARDS NOTES: Required Open Space .40 <br /> [1] R= residential, NR= non-residential CU—G ditiGRal use. Ratio, min. <br /> [2] Required side and rear setbacks adjacent to residentially Gress Land-A°ram, <br /> zoned land shall be equal to the required side or rear setback of Minx NR--CU <br /> the adjacent residential district. �QA o foot) rye <br /> [3]Two feet of additional height shall be allowed for one foot <br /> increase of the required front and side setbacks. Required <br /> Pedestrian/Landscape .05 <br /> Ratio, min. <br /> DEVELOPMENT1-2 DISTRICT SPECIFIC D• -D <br /> 1. Uses shall be restricted to those indicated for the 1-2 District in Section 5.2, unless a Conditional Use-(CU)o <br /> M p__rZ District is approved (see Section 3.8). Additionally, non-residential uses are restricted based on <br /> the Watershed Protection Overlay District in which the property is located. Refer to Section 4.2.3 for land <br /> use restrictions. <br /> 2. Development within the zoning district shall be subject to all applicable use standards detailed in Article 5 <br /> and all applicable development standards detailed in Article 6 of this Ordinance. See Sections 6.2.5 and <br /> 6.2.6 if more than one principal use or principal structure is proposed on a non-residential zoning lot. <br /> 3. Residential uses are not permitted in this district. <br /> 4. Allowable impervious surface area is based on the Watershed Protection Overlay District in which the <br /> property is located. Refer to Section 4.2.6 for a breakdown of the allowable impervious surface area. <br /> Additionally, Section 4.2.6 may require a larger lot size for non-residential uses than is contained in the <br /> Dimensional and Ratio Standards Table. <br /> 5. For lots outside of a Watershed Protection Overlay District(see Section 4.2), the minimum usable lot area <br /> for lots that utilize ground absorption wastewater systems shall be 30,000 square feet for parcels between <br /> 40,000 square feet and 1.99 acres in size; zoning lots two acres and greater in size shall have a minimum <br /> usable lot area of at least 40,000 square feet. <br /> 6. Access shall consist of direct vehicular access to streets designated either arterial or collector by the <br /> adopted Comprehensive Plan.Access to rail service is desirable but not required. <br /> 7. Proposed subdivisions are subject to all applicable subdivision standards detailed in Article 7. Note that <br /> Article 7 provides for different dimensional requirements than those shown in the Dimensional and Ratio <br /> Standards table depending upon the type of subdivision proposed and the percentage of open s ace <br /> Orange County, North Carolina—Unified Development Ordinance Page 3-36 <br />
The URL can be used to link to this page
Your browser does not support the video tag.