Orange County NC Website
DocuSign Envelope ID:D561B1AE-DF34-4907-AD06-AOEB37BBE427 <br /> CHAPEL HILL ORANGE COUNTY VISITORS BUREAU August 12,2020 <br /> 308 WEST FRANKLIN,CHAPEL HILL,NC <br /> D. Product List: For each product indicated, include the following: <br /> 1. Cross-reference to finish system and locations of application areas. Use same <br /> designations indicated on Drawings and in schedules. <br /> 2. Printout of MPI's current "MPI Approved Products List" for each product category <br /> specified in Part 2,with the product proposed for use highlighted. <br /> 1.4 QUALITY ASSURANCE <br /> A. MPI Standards: <br /> 1. Products: Complying with MPI standards indicated and listed in its "MPI Approved <br /> Products List." <br /> 2. Preparation and Workmanship: Comply with requirements in "MPI Architectural <br /> Painting Specification Manual" for products and finish systems indicated. <br /> B. Mockups: Apply benchmark samples of each finish system indicated and each color selected to <br /> verify preliminary selections made under sample submittals and to demonstrate aesthetic effects <br /> and set quality standards for materials and execution. <br /> 1. Architect will select one surface to represent surfaces and conditions for application of <br /> each type of finish system and substrate. <br /> a. Vertical and Horizontal Surfaces: Provide samples of at least 10 sq. ft. <br /> b. Other Items: Architect will designate items or areas required. <br /> 2. Final approval of stain color selections will be based on benchmark samples. <br /> a. If preliminary stain color selections are not approved, apply additional benchmark <br /> samples of additional stain colors selected by Architect at no added cost to Owner. <br /> 1.5 DELIVERY, STORAGE,AND HANDLING <br /> A. Store materials not in use in tightly covered containers in well-ventilated areas with ambient <br /> temperatures continuously maintained at not less than 45 deg F(7 deg C). <br /> 1. Maintain containers in clean condition, free of foreign materials and residue. <br /> 2. Remove rags and waste from storage areas daily. <br /> 1.6 PROJECT CONDITIONS <br /> A. Apply finishes only when temperature of surfaces to be finished and ambient air temperatures <br /> are between 50 and 95 deg F (10 and 35 deg C). <br /> B. Do not apply exterior finishes in snow, rain, fog, or mist; when relative humidity exceeds 85 <br /> percent; at temperatures less than 5 deg F (3 deg C) above the dew point; or to damp or wet <br /> surfaces. <br /> STAINING AND TRANSPARENT FINISHING 099300 -2 <br />