Browse
Search
Agenda - 12-15-2020; 5-b - Zoning Atlas Amendment - Master Plan Development Conditional Zoning District (MPD-CZ) for Efland Station (formerly Beaver Crossing)
OrangeCountyNC
>
BOCC Archives
>
Agendas
>
Agendas
>
2020
>
Agenda - 12-15-20 Virtual Business Meeting
>
Agenda - 12-15-2020; 5-b - Zoning Atlas Amendment - Master Plan Development Conditional Zoning District (MPD-CZ) for Efland Station (formerly Beaver Crossing)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2020 3:19:39 PM
Creation date
12/10/2020 2:49:47 PM
Metadata
Fields
Template:
BOCC
Date
12/15/2020
Meeting Type
Business
Document Type
Agenda
Agenda Item
5-b
Document Relationships
Agenda 12-15-2020 Virtual Business Meeting
(Message)
Path:
\BOCC Archives\Agendas\Agendas\2020\Agenda - 12-15-20 Virtual Business Meeting
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
204
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
62 <br /> Kimley>>>Horn Page 19 <br /> 3. The map will need to be modified to include the detailed design calculations for the <br /> project indicating that the proposed utility lines are sufficient for expected development <br /> and associated/estimated density for the project. <br /> Response: Anticipated design flows for sanitary sewer and potable water are now <br /> shown on a table on Sheet C4.0 (Water and Sewer Map). <br /> 4. Include a note indicating: 'All onsite utilities shall be underground unless approved by the <br /> Board of County Commissioners'. <br /> Response: The requested note has been added to Sheet C4.0 (Water and Sewer <br /> Map). <br /> 5. Indicate connection points to various utility lines. <br /> Response: Connection points have been called out on Sheet C4.0 (Water and <br /> Sewer Map). <br /> 6. Denote the location of any anticipated/planned utility infrastructure (i.e. pump stations, <br /> etc.). <br /> Response: The location of anticipated infrastructure is provided on the plans. See <br /> Sheet C4.0 for details. <br /> 7. Provide detail on anticipated fire flow for the proposed utility lines with detail on how <br /> same will support the project. As a general reminder, fire flow requirements are <br /> necessary for consideration when sizing water lines. <br /> Response: A note has been added to Sheet C4.0 detailing the anticipated fire flow <br /> and potential improvements required. <br /> 8. Provide detail on the anticipated placement of manholes and elevations same. This will <br /> include the provision of a typical manhole construction detail. <br /> Response: Anticipated manhole locations are shown on the plans, and elevations <br /> for existing structures are shown on sheet C1.0 Existing Conditions. Proposed <br /> structures will tie into existing structures, and the proposed elevations will <br /> primarily be driven by site grading to be determined at the Site Plan level. <br /> 9. Denote anticipated stub out locations. <br /> Response: Anticipated stub out locations are shown on the plan. Refer to Sheet <br /> C4.0 for details. <br /> 10. Additional detail on expected build-out. This information shall be essential in evaluating <br /> the ability of installed infrastructure to meet current and future needs of the project. <br /> Response: A note detailing additional water needs for the full build-out has been <br /> i <br /> added to Sheet C4.0 (Water and Sewer Map). <br /> Engineering Comments: <br /> A. General: <br /> i. Orange County requests that the applicant consider Orange County's proposed recordation of <br /> up to four (4) 30-ft wide public sanitary sewer easements as shown on the attached redlines. <br /> 00 Morris Street, 00 Durham, NC 27701 • .: <br />
The URL can be used to link to this page
Your browser does not support the video tag.