Orange County NC Website
34 <br /> 1 ix. Equipment (i.e. HVAC, elevator overrides, etc.) shall be screened utilizing <br /> 2 1 of the following methods: <br /> 3 1. Clad in exterior materials that are non-reflective or illuminated, OR <br /> 4 2. Designed as an architectural feature of the proposed structure, OR <br /> 5 3. Screened through some vegetative buffer or fencing. <br /> 6 x. All buildings constructed within the Project shall be Energy Star certified at <br /> 7 the time of construction (or in the discontinuance of such certification, <br /> 8 substantially in compliance with the former certification requirements) and, <br /> 9 after issuance of a certificate of compliance (CoC), all installed systems <br /> 10 shall receive proper maintenance in the ordinance course of businesses; <br /> 11 xi. Development within the Project shall utilize LED lighting for interior and <br /> 12 exterior lights, or future successor technology, except in areas where use <br /> 13 of same could typically be prohibited (i.e. lab space, etc.); <br /> 14 xii. Development within the Project shall utilize rain reclamation devices <br /> 15 collecting rainwater for irrigation purposes <br /> 16 xiii. Buildings within the Project shall incorporate `cool roof' systems into their <br /> 17 design. The cool roof system is designed to deliver higher solar reflectance <br /> 18 (i.e. the ability to reflect the visible, infrared and ultraviolet wavelengths of <br /> 19 the sun, reducing heat transfer to the building, etc.) and higher thermal <br /> 20 emittance (the ability to radiate absorbed, or non-reflected solar energy) <br /> 21 than standard designed roofing products. <br /> 22 xiv. Motion control activated lighting shall be, where safety and internal <br /> 23 operations permit, used for all internal building lighting to prevent internal <br /> 24 lights being left on indefinitely; <br /> 25 xv. Bio retention basins(i.e. rain gardens)shall be incorporated into the Project <br /> 26 to capture and treat runoff from truck wells within proposed loading docks; <br /> 27 xvi. Low flow toilets and water fixtures shall be used within the Project for all <br /> 28 restroom facilities and where not associated with a manufacturing or <br /> 29 research process. <br /> 30 d. Landscaping/Buffering: In addition to the standards contained in Section 6.8 of <br /> 31 the LIDO, the following specific standards shall apply to the Project: <br /> 32 i. All required landscaping shall be installed and maintained by the developer <br /> 33 or their successor in perpetuity; <br />