Browse
Search
Planning Board - 110420 Agenda Packet
OrangeCountyNC
>
Advisory Boards and Commissions - Active
>
Orange County Planning Board
>
Agendas
>
2020
>
Planning Board - 110420 Agenda Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/29/2020 10:53:22 AM
Creation date
10/29/2020 10:49:20 AM
Metadata
Fields
Template:
BOCC
Date
11/4/2020
Meeting Type
Regular Meeting
Document Type
Agenda
Document Relationships
110420 Virtual Planning Board Minutes
(Message)
Path:
\Advisory Boards and Commissions - Active\Orange County Planning Board\Minutes\2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
188
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
as part of all site plan review. <br />g. Each site plan shall be required to demonstrate compliance with Section <br />6.16 Environmental Assessment of the UDO. In those cases where <br />development exceeds established thresholds, a formal Environmental <br />Impact Statement (EIS) may be required allowing for site plan approval; <br />h. In addition to the standards detailed in Section 2.5 of the UDO, all <br />landscaping plans shall include information denoting the proposed method <br />of care (i.e. underground sprinklers, maintenance personnel, etc.) for the <br />development. <br />i. Identified conflicts associated with landscaping shall be resolved prior to <br />the approval of the site plan for a given project; <br />j. For all site plans submitted for the Project the Efland Volunteer Fire <br />Department shall be considered a member of the County Development <br />Advisory Committee (DAC) as outlined in Section 1.9 of the UDO to review <br />a projects compliance with applicable development standards including, <br />but not necessarily limited to: land use regulations, conditions of MPD-CZ <br />approval, applicable State fire/building codes. <br />k. Site plans shall contain documentation outlining proposed and/or existing <br />cumulative impervious surface area as well as building/open space ratios <br />within the Project. <br />III. DIMENSIONAL STANDARDS: <br />a. The Project shall observe a building square footage limit of 500,000 sq.ft. <br />consistent with the submitted and approved Traffic Impact Analysis (TIA) <br />approved as part of this master concept plan. <br />Additional floor area may be developed with the submittal of a revised, <br />updated, TIA processed and reviewed in accordance with the provisions of <br />the UDO. <br />b. Height – Principal Structures: Consistent with the definition of building <br />height in Article 10 Definitions and Section(s) 6.2.2 and 6.5 3 of the UDO, <br />the following height limitations shall be observed within the Project: <br />i. Development Area 1 and 5: 40 ft. <br />ii. Development Area(s) 2 through 4: 60 ft. <br />iii. Development Area 6: 35 ft. <br />Measurement shall be taken from finished grade at the center point of the <br />front building façade. <br />169
The URL can be used to link to this page
Your browser does not support the video tag.