Browse
Search
Planning Board - 110420 Attachment 1
OrangeCountyNC
>
Advisory Boards and Commissions - Active
>
Orange County Planning Board
>
Agendas
>
2020
>
Planning Board - 110420 Attachment 1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/29/2020 10:49:09 AM
Creation date
10/29/2020 10:32:12 AM
Metadata
Fields
Template:
BOCC
Date
11/4/2020
Meeting Type
Regular Meeting
Document Type
Agenda
Document Relationships
110420 Virtual Planning Board Minutes
(Message)
Path:
\Advisory Boards and Commissions - Active\Orange County Planning Board\Minutes\2020
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1075
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
West Orange Site Build Saturday <br />5: US-70/I-40 Connector Road & I-40 EB Service Road/I-40 EB Entrance Ramp 06/09/2020 <br />K:\DUR_LDEV\013284003 West Orange Site\T4 - Analysis\Synchro\Build Saturday.syn <br />Kimley-Horn Synchro 10 Report <br />Lane Group EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR <br />Lane Configurations <br />Traffic Volume (vph) 785 4 4 0 0 0 0 43 4 581 39 0 <br />Future Volume (vph) 785 4 4 0 0 0 0 43 4 581 39 0 <br />Ideal Flow (vphpl)1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 <br />Storage Length (ft)400 125 0 0 0 40 400 0 <br />Storage Lanes 1 0 0 0 0 1 1 0 <br />Taper Length (ft)100 25 25 100 <br />Satd. Flow (prot)1681 1685 0 0 0 0 0 1863 1583 1770 1863 0 <br />Flt Permitted 0.950 0.953 0.726 <br />Satd. Flow (perm)1681 1685 0 0 0 0 0 1863 1583 1352 1863 0 <br />Right Turn on Red Yes Yes Yes Yes <br />Satd. Flow (RTOR)36 <br />Link Speed (mph)50 50 45 45 <br />Link Distance (ft)1140 702 378 714 <br />Travel Time (s)15.5 9.6 5.7 10.8 <br />Peak Hour Factor 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 <br />Shared Lane Traffic (%) 50% <br />Lane Group Flow (vph) 436 444 0 0 0 0 0 48 4 646 43 0 <br />Number of Detectors 1 1 1 1 1 1 <br />Detector Template Left <br />Leading Detector (ft) 20 40 106 40 40 106 <br />Trailing Detector (ft)0 0 100 0 0 100 <br />Detector 1 Position(ft) 0 0 100 0 0 100 <br />Detector 1 Size(ft)20 40 6 40 40 6 <br />Detector 1 Type Cl+Ex Cl+Ex Cl+Ex Cl+Ex Cl+Ex Cl+Ex <br />Detector 1 Channel <br />Detector 1 Extend (s)0.0 0.0 0.0 0.0 0.0 0.0 <br />Detector 1 Queue (s)0.0 0.0 0.0 0.0 0.0 0.0 <br />Detector 1 Delay (s)0.0 0.0 0.0 0.0 0.0 0.0 <br />Turn Type Perm NA NA Perm Perm NA <br />Protected Phases 4 2 6 <br />Permitted Phases 4 2 6 <br />Detector Phase 4 4 2 2 6 6 <br />Switch Phase <br />Minimum Initial (s)7.0 7.0 12.0 12.0 12.0 12.0 <br />Minimum Split (s)15.0 15.0 20.0 20.0 20.0 20.0 <br />Total Split (s)44.0 44.0 76.0 76.0 76.0 76.0 <br />Total Split (%)36.7% 36.7%63.3% 63.3% 63.3% 63.3% <br />Yellow Time (s)5.0 5.0 5.0 5.0 5.0 5.0 <br />All-Red Time (s)2.0 2.0 2.0 2.0 2.0 2.0 <br />Lost Time Adjust (s) -2.0 -2.0 -2.0 -2.0 -2.0 -2.0 <br />Total Lost Time (s)5.0 5.0 5.0 5.0 5.0 5.0 <br />Lead/Lag <br />Lead-Lag Optimize? <br />Recall Mode None None C-Max C-Max C-Max C-Max <br />Act Effct Green (s)36.4 36.4 73.6 73.6 73.6 73.6 <br />Actuated g/C Ratio 0.30 0.30 0.61 0.61 0.61 0.61 <br />v/c Ratio 0.85 0.87 0.04 0.00 0.78 0.04 <br />Control Delay 54.6 56.1 10.3 0.0 24.6 6.2 <br />351
The URL can be used to link to this page
Your browser does not support the video tag.