Browse
Search
Planning Board - 110420 Attachment 1
OrangeCountyNC
>
Advisory Boards and Commissions - Active
>
Orange County Planning Board
>
Agendas
>
2020
>
Planning Board - 110420 Attachment 1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/29/2020 10:49:09 AM
Creation date
10/29/2020 10:32:12 AM
Metadata
Fields
Template:
BOCC
Date
11/4/2020
Meeting Type
Regular Meeting
Document Type
Agenda
Document Relationships
110420 Virtual Planning Board Minutes
(Message)
Path:
\Advisory Boards and Commissions - Active\Orange County Planning Board\Minutes\2020
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1075
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> <br /> <br />30 NELSON MULLINS RILEY & SCARBOROUGH LLP <br /> For informational purposes only. Past success does not indicate the likelihood of success in any future legal representation. <br />x Maximum 1.0 foot-candle at all other adjacent property lines. <br /> <br />x No restriction on the maximum foot-candles within Development Area 1. <br /> <br />x Maximum 36’ pole height. <br /> <br />x All fixtures shall be full cutoff design. <br /> <br />x No restrictions on placement of fixtures if foot-candle and height requirements listed above are <br />met. <br /> <br />x Lighting shall comply with all NCDOT standards. <br /> <br />2. Development Areas 2–5. For Development Areas 2–5, a formal lighting plan shall be submitted <br />with all site plans where outdoor lighting is shown demonstrating compliance with applicable County <br />regulations per Section 6.11 of the UDO with the following allowances: <br /> <br />x There shall be no net increase in Existing Light Levels along the Interstate 40/85 service road <br /> <br />x Maximum 0.5 foot-candle at all other adjacent property lines. <br /> <br />x No restriction on the maximum foot-candles within the Development Area. <br /> <br />x Maximum 36’ pole height. <br /> <br />x All fixtures shall be full cutoff design. <br /> <br />x Lighting shall comply with all NCDOT requirements. <br /> <br />x All security lights shall abide by requirements of section 6.11.3(J) of the UDO. <br /> <br />H. Sustainable Design & Development Initiatives <br /> <br />(NOTE THAT DEPICTIONS BELOW ARE FOR ILLUSTRATIVE PURPOSES ONLY AND DO NOT <br />REPRESENT ACTUAL DESIGN REQUIREMENTS). <br /> <br />1. Project will encourage integration of geographically relevant sustainable design features where <br />practical, including: <br /> <br />x Rainwater harvesting for landscape irrigation mitigation and solar infrastructure installations on <br />rooftops or in adjacent areas as part of associated building design. <br />x Other possible renewables. <br />x See Section 3-2 for reservation of Development Area 6 for transit supportive facilities. <br />x Consideration of L.E.E.D certified practices for components of the Project where feasible. <br />34
The URL can be used to link to this page
Your browser does not support the video tag.