Browse
Search
Planning Board - 110420 Attachment 1
OrangeCountyNC
>
Advisory Boards and Commissions - Active
>
Orange County Planning Board
>
Agendas
>
2020
>
Planning Board - 110420 Attachment 1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/29/2020 10:49:09 AM
Creation date
10/29/2020 10:32:12 AM
Metadata
Fields
Template:
BOCC
Date
11/4/2020
Meeting Type
Regular Meeting
Document Type
Agenda
Document Relationships
110420 Virtual Planning Board Minutes
(Message)
Path:
\Advisory Boards and Commissions - Active\Orange County Planning Board\Minutes\2020
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1075
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
West Orange Site Build AM <br />3: Mt. Willing Road & I-40 WB Entrance Ramp/I-40 WB Service Road 06/09/2020 <br />K:\DUR_LDEV\013284003 West Orange Site\T4 - Analysis\Synchro\Build AM.syn Synchro 10 Report <br />Kimley-Horn Page 5 <br />Lane Group EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR <br />Lane Configurations <br />Traffic Volume (vph)0 0 0 46 97 173 16 98 0 0 747 48 <br />Future Volume (vph)0 0 0 46 97 173 16 98 0 0 747 48 <br />Ideal Flow (vphpl)1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 <br />Storage Length (ft)0 0 280 0 225 0 0 200 <br />Storage Lanes 0 0 1 1 1 0 0 1 <br />Taper Length (ft)25 100 75 25 <br />Satd. Flow (prot)0 0 0 1770 1863 1583 1770 1863 0 0 1863 1583 <br />Flt Permitted 0.950 0.243 <br />Satd. Flow (perm)0 0 0 1770 1863 1583 453 1863 0 0 1863 1583 <br />Right Turn on Red Yes Yes Yes Yes <br />Satd. Flow (RTOR)192 73 <br />Link Speed (mph)50 50 45 45 <br />Link Distance (ft)652 567 655 1860 <br />Travel Time (s)8.9 7.7 9.9 28.2 <br />Peak Hour Factor 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 <br />Shared Lane Traffic (%) <br />Lane Group Flow (vph) 0 0 0 51 108 192 18 109 0 0 830 53 <br />Number of Detectors 1 1 1 1 1 1 1 <br />Detector Template <br />Leading Detector (ft)40 40 40 40 106 106 40 <br />Trailing Detector (ft)0 0 0 0 100 100 0 <br />Detector 1 Position(ft)0 0 0 0 100 100 0 <br />Detector 1 Size(ft)40 40 40 40 6 6 40 <br />Detector 1 Type Cl+Ex Cl+Ex Cl+Ex Cl+Ex Cl+Ex Cl+Ex Cl+Ex <br />Detector 1 Channel <br />Detector 1 Extend (s)0.0 0.0 0.0 0.0 0.0 0.0 0.0 <br />Detector 1 Queue (s)0.0 0.0 0.0 0.0 0.0 0.0 0.0 <br />Detector 1 Delay (s)0.0 0.0 0.0 0.0 0.0 0.0 0.0 <br />Turn Type Perm NA Perm Perm NA NA Perm <br />Protected Phases 8 2 6 <br />Permitted Phases 8 8 2 6 <br />Detector Phase 8 8 8 2 2 6 6 <br />Switch Phase <br />Minimum Initial (s)7.0 7.0 7.0 12.0 12.0 12.0 12.0 <br />Minimum Split (s)15.0 15.0 15.0 20.0 20.0 20.0 20.0 <br />Total Split (s)16.0 16.0 16.0 44.0 44.0 44.0 44.0 <br />Total Split (%)26.7% 26.7% 26.7% 73.3% 73.3%73.3% 73.3% <br />Yellow Time (s)5.0 5.0 5.0 5.0 5.0 5.0 5.0 <br />All-Red Time (s)2.0 2.0 2.0 2.0 2.0 2.0 2.0 <br />Lost Time Adjust (s)-2.0 -2.0 -2.0 -2.0 -2.0 -2.0 -2.0 <br />Total Lost Time (s)5.0 5.0 5.0 5.0 5.0 5.0 5.0 <br />Lead/Lag <br />Lead-Lag Optimize? <br />Recall Mode None None None C-Max C-Max C-Max C-Max <br />Act Effct Green (s)10.3 10.3 10.3 39.7 39.7 39.7 39.7 <br />Actuated g/C Ratio 0.17 0.17 0.17 0.66 0.66 0.66 0.66 <br />v/c Ratio 0.17 0.34 0.45 0.06 0.09 0.67 0.05 <br />Control Delay 22.6 25.0 10.5 4.4 4.1 9.8 0.9 <br />311
The URL can be used to link to this page
Your browser does not support the video tag.