Browse
Search
Agenda - 10-20-20; 6-a - Zoning Atlas Amendment - Master Plan Development Conditional Zoning District (MPD-CZ) for the Research Triangle Logistics Park (RTLP)
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
2020's
>
2020
>
Agenda - 10-20-20 Virtual Business Meeting
>
Agenda - 10-20-20; 6-a - Zoning Atlas Amendment - Master Plan Development Conditional Zoning District (MPD-CZ) for the Research Triangle Logistics Park (RTLP)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/15/2020 4:38:53 PM
Creation date
10/15/2020 4:50:45 PM
Metadata
Fields
Template:
BOCC
Date
10/20/2020
Meeting Type
Business
Document Type
Agenda
Agenda Item
6-a
Document Relationships
Minutes 10-20-2020 Virtual Business Meeting
(Message)
Path:
\Board of County Commissioners\Minutes - Approved\2020's\2020
ORD-2020-022 Ordinance Amending The Orange County Zoning Atlas
(Message)
Path:
\Board of County Commissioners\Ordinances\Ordinance 2020-2029\2020
OTHER-2020-010 Statement of Consistency of A Proposed Unified Development Ordinance Map Amendment w-Adopted Orange County 2030 Comprehensive Plan - Applicant initiated Amendment rezone 3 parcels
(Message)
Path:
\Board of County Commissioners\Various Documents\2020 - 2029\2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ii. Accessory Structures: Water tower shall not exceed 90 ft. 7 <br />c. Setbacks: <br />i. Structures shall observe: <br />1. 100 ft. setback from exterior property lines abutting <br />residentially zoned property; <br />1.2. and the120 ft. setback from Davis Road right-of-way;8 <br />2.3. 50 ft. setback from property exterior lines abutting non- <br />residentially zoned property and the Service Road right-of- <br />way. <br />ii. Vehicular use areas shall observe: <br />1. 50 ft100 ft. setback from exterior property lines abutting <br />residentially zoned property except as defined below; <br />a. Access road/parking area along the western boundary <br />line, adjacent to PIN 9863-53-9059, shall be permitted <br />observing a 50 ft. setback; and <br />1.b. An access road along the southern property <br />line, affording interior access from the Project to PIN <br />9862-99-8894, shall be permitted observing a 50 ft. <br />setback. 9 <br />2. 50 ft. setback for access roads/drives running parallel with <br />Davis Road;10 <br />2.3. 25 ft. setback from property lines abutting non- <br />residentially zoned property and the Service Road right-of- <br />way. <br />iii. Interior lot line setbacks: 11 <br />1. Structures: 20 ft. from all interior property lines; <br /> <br />7 Staff is recommended a 90 ft. height limit for proposed water towers. The application submittal makes no <br />reference to any additional use that would need to exceed established height limits. <br />8 Language suggested/recommended by the applicant to address setbacks for structures erected on the Davis Road <br />property. <br />9 The applicant has requested modification of vehicular use setbacks as detailed herein. In the first instance, the <br />area adjacent to the Project on PIN 9863‐53‐9059 is heavily encumbered by floodplain and required buffers. The <br />applicant suggests allowing for an access road/parking in this area will not impact development on the adjacent <br />parcel as same is already limited due to the presence of mapped floodplain. In the second instance, the applicant <br />is seeking to reduce the required land use buffer to allow for the location of an access road in an area that will <br />have the least impact on existing floodplain. If the applicant is required to observe a 100 ft. buffer in this area, the <br />required roadway crossing could have more environmental impact on the floodplain and floodplain buffers in the <br />area. <br />10 Language suggested/recommended by the applicant to address access management issues along Davis Road. <br />While no parking is intended within this area, driveway access will be necessary. <br />11 A new condition designed to address BOCC comments from the October 6, 2020 meeting seeking clarification on <br />internal setback requirements. <br />16
The URL can be used to link to this page
Your browser does not support the video tag.