Browse
Search
BOH Agenda 022620
OrangeCountyNC
>
Advisory Boards and Commissions - Active
>
Board of Health
>
Agendas
>
2020
>
BOH Agenda 022620
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/5/2020 1:35:02 PM
Creation date
10/5/2020 11:16:52 AM
Metadata
Fields
Template:
BOCC
Date
2/26/2020
Meeting Type
Regular Meeting
Document Type
Agenda
Document Relationships
BOH Minutes of 022620
(Attachment)
Path:
\Advisory Boards and Commissions - Active\Board of Health\Minutes\2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
storage tanks(except compressed gas) <br /> i with secondary containment 50 ft <br /> ii without secondary containment 100 ft <br /> Above ground or underground storage tanks containing petroleum fuels <br /> used for heating equipment, boilers or furnaces with the exception of tanks 50 ft <br /> used solely for storage of propane, natural gas, or LP <br /> All other petroleum or chemical storage tanks stems 100 ft <br /> Gravesites 50 ft <br /> All other potential sources of groundwater contamination 50 ft <br /> Property lines where available 40 ft <br /> In-ground swimming pools 25 f Comment[VH50]:NECESSARY TO ADD FOR <br /> Solar ground-mounted array 50 ft EXISTING SYSTEM AUTHORIZATIONS <br /> Comment[VH51]:NECESSARYTO ADD FOR <br /> 3. For a well on a lot serving a single-family dwelling where lot size or other fixed EXISTING SYSTEM AUTHORIZATIONS <br /> conditions preclude the separation distances specified in Subparagraph (A)(2)of this <br /> Rule, the required horizontal separation distances shall be the maximum possible but <br /> shall in no case be less than the following: <br /> Septic tank, pump tank, pretreatment components and drainfield including 50 ft <br /> drainfield repair areas, except saprolite systems as defined in 15A NCAC 18A <br /> .1956(6) <br /> Water-tight sewage or liquid-waste collection or transfer facility constructed to 25 ft <br /> water main standards in accordance with 15A NCAC 02T .0305(g) (2)or <br /> Orange County Regulations for Wastewater Treatment and Disposal Systems <br /> rule .1950 e , as applicable <br /> Animal barns 50 ft <br /> Existing building foundations 25 ft <br /> Property lines loft <br /> Existing in-ground swimming pools 25 ft <br /> Land-based or subsurface waste storage or disposal systems 50 ft <br /> 4. Minimum separation distances from all other potential sources of groundwater <br /> contamination shall be those specified in Subparagraph (A)(2)of this Rule. <br /> 5. No person shall cause a potential source of groundwater contamination as described <br /> in Section II (A)(2)or Section II (A)(3)of these Rules to be placed closer to a well <br /> site or an existing well than the referenced distances specified. <br /> History Note: Substitute for NCAC 02C.0107 <br /> Eff. July 1, 2008;Amended eff. October 23, 2009;March 25, 2020 <br /> B. SOURCE OF WATER <br /> 1.The source of water for any water supply well shall not be from a water bearing zone <br /> or aquifer that is contaminated. <br /> 2. If a well is constructed to obtain water from an unconsolidated rock formation, prior <br /> approval from the OCHD shall be required. The well shall be equipped with a screen <br /> or screens to prevent the entrance of formation material into the well after the well <br /> 19 <br />
The URL can be used to link to this page
Your browser does not support the video tag.