Browse
Search
2020-259-E AMS-LRC Indoor Testing and Research environmental quality inspection
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2020
>
2020-259-E AMS-LRC Indoor Testing and Research environmental quality inspection
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2020 2:53:26 PM
Creation date
5/6/2020 2:41:47 PM
Metadata
Fields
Template:
BOCC
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 15092B8F-0126-44C5-817A-8F730D62BC94 <br /> LRC Indoor Testing&Research,Inc. <br /> - LAIC140 Iowa Lane,Suite 102 <br /> Q--LI <br /> 4Pr Tiykinn�rfintie�:cr. <br /> Cary, NC 27511 <br /> (919)342-4936 <br /> www.ircresearch.com <br /> April 15, 2020 <br /> Orange County <br /> Mr.Alan Dorman <br /> 131 West Margaret Lane <br /> Hillsborough, NC 27278 <br /> Authorization for Payment of Services Provided <br /> Re: Limited Environmental Indoor Environmental Quality Investigation with the Collection of Non-Viable Air and Surface Samples <br /> at 137 West Margaret Lane, Hillsborough, NC 27278(HR File Room) <br /> LRC Indoor Testing& Research, Inc. is pleased to provide this proposal for Indoor Environmental Quality(IEQ) services related to the <br /> structure at the address listed above. This proposal covers labor for sample collection, data analysis, laboratory fees for measuring <br /> airborne fungi and surface fungi,and report writing. <br /> Based on our conversation we propose the following tasks: <br /> 1. Visual inspection of the impacted areas of the structure. <br /> 2. Record Indoor Air Quality parameters of temperature and relative humidity in the structure. <br /> 3. Check building materials moisture content in representative suspect areas. <br /> 4. Collect representative fungal spore trap air screening samples indoors and outdoors for comparison for non-viable fungal analysis. <br /> At least one of the samples indoors will be collected at the return with the fan of the HVAC operating. <br /> 5. Collect representative surface sample(s)for non-viable fungal analysis. <br /> 6. Provide a written report describing the inspection results and comparing those results to accepted guidelines and directives. <br /> Our report will include a summary of our inspection,Certificates of Laboratory Analysis,Summary Tables, and remediation protocol. <br /> LRC's proposed fee for the investigation is: <br /> Amount Description Each Total <br /> 1 Project Fee* $ 300.00 $ 300.00 <br /> 3 Non-Viable Air Samples $ 35.00 $ 105.00 <br /> 1 Non-Viable Surface Samples $ 35.00 $ 35.00 <br /> Lab Fees $ <br /> Additional Fees $ <br /> ESTIMATED TOTAL $ 440.00 <br /> *This fee is charged for sample and data collection,sample analysis and report writing for a field team.The proposed cost is an estimate based on our conversation.If <br /> the investigation is more extensive and involving more areas,the price will be adjusted but will be discussed with you while we are on site.We request payment of 60% <br /> of the total upon completion of our investigation and the remainder on submission of our report.We accept Visa,MasterCard or a check at the time of our investigation. <br /> If the proposal is acceptable,please sign and return a copy to serve as our notice to proceed.An email confirmation is acceptable. Thank you for the opportunity to <br /> work on this project. <br /> After the completion of remediation, clearance testing is highly recommended. There is an additional cost for the clearance <br /> investigation and a post remediation clearance report will be issued at that time. <br /> If this is an insurance claim you, the client, are ultimately responsible for the payment for this project regardless of the insurance <br /> company's final decision on payment. <br /> Proposal offered by: Proposal accepted by: <br /> n� <br /> Cathy Richmond at LRC Indoor Research and Testing <br />
The URL can be used to link to this page
Your browser does not support the video tag.