Orange County NC Website
21 <br /> PLANS PREPARED FOR: <br /> NOTES:_ <br /> 1. SITE PLAN SHOWN BELOW WAS REPRODUCED FROM INFORMATION verizonv <br /> PROVIDED BY ORANGE COUNTY GIS MAPS. CONTRACTOR TO VERIFY <br /> ALL EXISTING INFORMATION IS AS INDICATED ON SITE PLAN. <br /> CONTRACTOR IS TO ESTABLISH THE EXISTENCE AND LOCATION OF 8921 Research Drive <br /> ALL EXISTING UNDERGROUND AND OVERHEAD UTILITIES. IMMEDIATELY Charlotte,NC 28262 <br /> NOTIFY THE CONSTRUCTION MANAGER OF ANY DISCREPANCIES. (704)519-9957 <br /> 2. EXISTING INFORMATION INDICATED ON THE SITE PLAN SHOWN WAS <br /> PROJECT INFORMATION: <br /> REPRODUCED FROM MAPS PROVIDED BY ORANGE COUNTY. TEP DOES/R <br /> NOT GUARANTEE, OR ENSURE THE PRECISION, ACCURACY OR VZW SITE NAME: SMC <br /> CORRECTNESS AND ASSUMES NO RESPONSIBILITY OR LIABILITY FOR ORANGE COUNTY <br /> DAMAGES, LOSS OF REVENUE, OR INJURY THAT MIGHT OCCUR. <br /> PROPOSED WOOD FENCE WTH 3' MAN SPORTS COMPLEX <br /> GATE TO SCREEN WALL—MOUNTED 101 MEADOWLANDS DRIVE <br /> EXISTING HVAC EQUIPMENT. SEE SHEET C-4 FOR HILLSBOROUGH,NC 27278 <br /> EQUIPMENT DETAILS. FINISHED SLATS TO FACE <br /> OUTWARD TOWARD ROAD. (ORANGE COUNTY) <br /> PROPOSED VEGETATION. PLANS PREPARED BY: <br /> SEE SHEETS L-1 &L-2 PROPOSED VERIZON 100A <br /> FOR DETAILS. OUTDOOR RATED NEMA 3 <br /> POWER PANEL BY EATON <br /> (P/N: CH22B10OR).SEE `I <br /> SHEET E-2 FOR DETAILS, 0PROPOSED FIBER TO PROPOSED WALL—MOUNTED IN, <br /> SOURCE. SEE SHEET TRANSFORMER. SEE SHEET <br /> 0 <br /> C-1 FOR DETAILS.� E-2 FOR MORE DETAILS. �\ <br /> x 7 0'f i+•s� TOWER ENGINEERING PROFESSIONALS <br /> PROPOSED WALL—MOUNT r x 326 TRYON ROAD <br /> RADIO CAGE. SEE SHEET f1 + PROPOSED WALL—MOUNTED <br /> C-4 FOR ELEVATION. m k + x METER&DISCONNECT.SEE RALEGH,NO 27603-3530 <br /> + SHEET C-4 FOR ELEVATION. OFFICE:(919)661-63 <br /> WWW.fepgr pn <br /> r NC LICE 7 <br /> r <br /> EXISTING DRAINAGE + SEAL: <br /> DOWNPIPE(TYP) r <br /> i • C 0,111 <br /> r T irk . <br /> 0 �9 <br /> + r 1 PROPOSED UNDERGROUND POWER { !�i^�1 7'I <br /> i ROUTING FROM EXISTING 277/480V 2 �7GJSL . <br /> TRANSFORMER TO PROPOSED <br /> + CUSTOMER OWNED CT CABINET. SEEFfl38 <br /> EXISTING EXISTING GAS LINE r SHEET C-1 FOR DETAILS.ROOFTOP yk VG�N^��'r" <br /> � <br /> i PROPOSED CT CABINET BYrrM��� 4?ecera5er5,2°79 <br /> 1 EATON (P/N: 303614 RTCT). <br /> 1 SEE UTILITY NOTES ON C-1 9 12-09-19 CONSTRUCTION <br /> 1 <br /> AND APPENDIX FOR DETAILS. g I I-I I-19 CONSTRUCTION <br /> I <br /> 1 7 I I-01-15 CONSTRUCTION <br /> G 0I-24-I9 CONSTRUCTION <br /> i REV DATE ISSUED FOR: <br /> PROPOSED COAX ROUTING <br /> FROM PROPOSED RRU TO DRAWN BY:SAM CHECKED BY: SCa <br /> PROPOSED ANTENNA. SEE SHEET TITLE: <br /> SHEET C-1 FOR DETAILS. <br /> Ji <br /> PROPOSED ROOFTOP '� <br /> CABLE TRAY. SEE EQUIPMENT LAYOUT <br /> SHEET C-6 FOR <br /> DETAILS, <br /> i <br /> SHEET NUMBER: REVISION: <br /> EQUIPMENT LAYOUT ° 4 e j 9 <br /> SCALE; Y4" = 1'—O" SCALE IN FEET v LL TEPH: E3172 <br />