Browse
Search
Agenda - 06-05-2001-9e
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
2000's
>
2001
>
Agenda - 06-05-2001
>
Agenda - 06-05-2001-9e
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/29/2008 7:16:28 PM
Creation date
8/29/2008 10:32:47 AM
Metadata
Fields
Template:
BOCC
Date
6/5/2001
Document Type
Agenda
Agenda Item
9e
Document Relationships
Minutes - 06-05-2001
(Linked To)
Path:
\Board of County Commissioners\Minutes - Approved\2000's\2001
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
undarnental Series Item :Choosing the Best HVAC System <br />file:///c~/windows/TEMP/0,263 7, I b287,00.h <br />28 <br />Window-Mounted Air Conditioners and Heat Pumps <br />Window-mounted air conditioners and heat pumps cool yr heat individual conditioner <br />They have a low initial cost and are quick and easy to install. They are also used to s <br />a central heating or cooling system or to condition selected spaces when the central <br />shuts down. When used with a central system, the units usually serve only part of the <br />conditioned by the central system. In such applications, both the central system and <br />units are sized to cool the particular conditioned space adequately without the other <br />In other applications, where window units are added to supplement an inadequate e~ <br />system, they are selected and sized to meet the required capacity when both system <br />Window units require outside air and cannot be used for interior reoms. <br />Window units are factory-assembled with individual controls. However, when severs <br />used in a single space, the controls may be interlocked to prevent simultaneous hea <br />cooling. For energy management in hotels, motels and other hospitality applications, <br />on/off control system_may be used to de-energize units in unoccupied rooms. Other <br />consider when selecting window unit systems are that window units are built to appli; <br />standards, rather than building equipment standards, so they may have a relatively s <br />high energy usage. <br />Through-The-Wall Mounted Air Conditioners and Heat Pumps, PT. <br />PTHPs <br />Through-the-wall air-conditioners, packaged terminal air conditioners (PTACs), heat <br />packaged terminal heat pumps (PTHPs) incorporate acomplete selfi-contained air-c~ <br />direct-expansion (DK) cooling system, a heating system (gas, electric, hot water, or <br />controls, and fan in an individual package. They are designed to cool ar heat individ~ <br />Each space is an individual occupant-controlled zone into which cooled or heated air <br />discharged in response to thermostatic cantrol to meet space requirements. <br />These systems are usually installed in apartments, assisted-living facilities, hospitals <br />motels, office buildings, and schools. Units range from appliance grade to heavy-dut <br />commercial grade. <br />Unitary System Selection Guidelines <br />Unitary systems are selected when it is decided that a central HVAC system is too la <br />expensive for a particular project, or a combination system (central and unitary) is ne <br />certain areas or zones to supplement the central system. For example, unitary syste <br />frequently used for perimeter spaces in combination with a central all-air system that <br />interior building spaces. This combination will usually provide greater temperature ar <br />control, air quality, and air (conditioned air and ventilation air) distribution patterns, th <br />possible with central or unitary units alone. As with any HVAC system, bath the adva <br />the disadvantages of unitary systems should be carefully examined to ensure that th <br />selected will perform as intended far the particular application. <br />Factors to consider when selecting unitary systems include: <br />Heating and cooling capability can be provided at all times, independent of otl <br />in the building but basic systems do not provide close humidity control. Howe <br />humidity control is not needed for most applications. Close humidity control, if <br />computer room applications or the like, can be accomplished by selecting spE <br />purpose packaged units. Only the one unit and one temperature zone is affec <br />malfunctions. One drawback of unitary units is that the operating sound levels <br />high. Another is that appearance can be unappealing. Otherdisadvantages ai <br />filtration options may be limited and outdoor air economizers are not always a <br />provide low cost cooling. Also, condensate can be a problem ifi proper remove <br />provided. <br />Individual room control (on/off and temperature) is simple and inexpensive. H <br />because temperature control is usually two-position, there can be swings in rc <br />temperature. The air distribution can be adjusted by the occupant, but is limits <br />airtlow quantity is fixed by design. Ventilation air is provided whenever the cor <br />
The URL can be used to link to this page
Your browser does not support the video tag.