Browse
Search
Agenda - 05-29-2001 - 4a
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
2000's
>
2001
>
Agenda - 05-29-2001
>
Agenda - 05-29-2001 - 4a
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/29/2008 8:16:12 PM
Creation date
8/29/2008 10:32:10 AM
Metadata
Fields
Template:
BOCC
Date
5/29/2001
Document Type
Agenda
Agenda Item
4a
Document Relationships
Minutes - 05-29-2001
(Linked To)
Path:
\Board of County Commissioners\Minutes - Approved\2000's\2001
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ARTICLE 5 - DIMENSI.ONAL REQUIREMENTS (continued) <br />PLANNING STAFF <br />FINDINGS <br />Ordinance Reauirements <br />c) Required front setback - 40 <br />feet <br />d) Required side and rear <br />setback - 20 feet <br />e) Maximum building height - <br />25 feet <br />x Yes ~ No <br />x Yes ____ No <br />x Yes _ No <br />Compliance with lot coverage <br />and development intensity <br />standards is addressed in <br />Article 6. <br />EVIDENCE SUBMITTED TO <br />SUPPORT FINDINGS <br />The house is approximately <br />140 feet from the NC 57 right- <br />of-way line. <br />The house is approximately <br />280 feet to the closest <br />property boundary line. <br />No additions to the existing <br />two-story building are proposed <br />as part of this project. Per <br />Article 6.2.1 of the Zoning <br />Ordinance, the height of a <br />building may exceed the <br />maximum building height <br />established in Article 5 <br />provided that one foot <br />additional front and side <br />setbacks are provided for every <br />two feet of additional height. <br />PLANNING BOARD <br />FINDINGS <br />Yes No <br />_w___ Yes ~ Np <br />Yes ~ No <br />ARTICLE 6 -APPLICATION OF DEMINSIONAL REQUIREMENTS "Yes" indicates com lianceā¢ "No" indicates <br />non-compliance) <br /> PLANNING STAFF EVIDENCE SUBMITTED TO PLANNING BOARD <br /> FINDINGS SUPPORT FINDINGS FINDINGS <br />Ordinance Reauirements <br />Article 6 lists specific <br />standards, which apply to <br />various types of development <br />applications. <br />Article 6.12 contains those The land use intensity <br />development intensity calculations are shown on the <br />standards, which apply to site plan. <br />developments controlled by the <br />Land Use Intensity (LUI) <br />system. <br />a) Minimum gross land area - x Yes <br />No The applicant's site contains Yes <br />No <br />N/A _ 47.17 acres (including R/W) or _ <br />_____ <br /> 2,054,725 sq. ft. <br />b) Maximum gross land area - x Yes <br />No The gross land area is equal to Yes <br />No <br />N/A ~ the total tract + the linear road _ <br />_~____ <br /> frontage * the LUI rating (22). <br /> 2,054,725 + 18,326 <br /> 2,073,051 sq. ft.. <br />c) Maximum floor ratio - .84 x Yes <br />No The plans indicate 4,148 Yes <br />Na <br />The maximum amount of floor ~ existing sq. ft. at floor area. _ <br />_ <br />area permitted by ordinance is No new floor area is proposed. <br />182,428 sq. ft. <br />d) Required minimum open x Yes <br />No The existing site has Yes <br />No <br />space ratio -- sq. ft. _ 2,050,081 sq. ft. _ <br />The minimum amount of open <br />space is 1,741,363 sq. ft. <br />
The URL can be used to link to this page
Your browser does not support the video tag.