Browse
Search
2020-062-E AMS - FESS Jail sprinkler repair
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2020
>
2020-062-E AMS - FESS Jail sprinkler repair
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2020 9:45:36 AM
Creation date
1/29/2020 8:58:34 AM
Metadata
Fields
Template:
Contract
Date
1/29/2020
Contract Starting Date
8/28/2019
Contract Ending Date
3/15/2020
Contract Document Type
Contract
Amount
$185.00
Document Relationships
R 2020-062 AMS - FESS Jail sprinkler repair
(Attachment)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID:OD06F4BB-E2FB-4411-84B6-9253E8A2FOD4 <br /> V <br /> RALEIGH-DURHAM <br /> V131FESS haler+7c+lirnirr111�'ipc <br /> h1wrisAlle,NC27560 <br /> (o)9194 69.8099 <br /> FIRE PROTECTION ❑r8%35a6040 <br /> NC State License Number 25532 <br /> Additional proposed inspection services such as but nat limited to Annual Fire Back ois,FwipardFlo►v 5--Year Inlernal <br /> Inuestigalion 5-Year alarm valve obstruclion invesllgation, 5-Year Hydrostatic test on FDCpining 5-3 ear infernal FDC <br /> check valve itaspeclion 5-Year Stand pipe internal pipe ohslrarcfio+r invesli alion 5-Year Stand pipe Flosif Test 3-1'ear air leak <br /> test 10 20 50- ear old fire s rinkler head test etc... Are required per Iota!, state and NFPA-25 Code. Fess Fire Protection <br /> Inspectors make no recommendations for system improvements during an NFPA-25 inspection,only listing deficiencies that <br /> are currently required by code to be corrected to the best of his or her knowledge at the time of inspection,You may <br /> receive an addendum to the report,this is not be considered part of the NFPA-25 report. <br /> Deficiencies Found During the Annual Fire Sprinkler Inspection 06/28/2019 <br /> Grange County-Jai!-Magistrates Office-125 Court Street-Hillsborough NC 27278 <br /> No 5-Year inspection tag found. <br /> No 3-Year air leak test tag found. <br /> Need hydrostatic test on FDC piping. <br /> No hydraulic data plate.(See(Vote Below) <br /> Gauges are outdated. <br /> Control valves are not locked or supervised. <br /> Low air and alarm devices are not wired.(See Note Below) <br /> No as built drawings on site,(could only find one sprinkler in jail in mop room.) <br /> NOTE: Na hydraulic data plate on either system. (Customer will need an engineer survey of the building and a <br /> complete drawing with calculations to replace the data plates. Let us know if you would like a quote.) <br /> IMPORTANT NOTE:You will need to get your Fire Alarm Company to wire the low-pressure switch and alarm switch to the <br /> FACP. If your system is activated due to a fire,freeze up,or leak the FACP will not report and fire trucks will not be <br /> dispatched. <br /> a division of Commercial Services,Inc,I=vivw.fessinc.net <br /> SUPPRESSIONFIRE EXTINGUISHERS I SPRINKLER I <br /> CHARLOTTE • RALEIGH-DURHAM • wINSTON-SALEM • GREENSBORO • CHARLESTON <br />
The URL can be used to link to this page
Your browser does not support the video tag.