Browse
Search
2020-060-E AMS - FESS Whitted sprinkler repair
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2020
>
2020-060-E AMS - FESS Whitted sprinkler repair
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2020 9:34:03 AM
Creation date
1/29/2020 8:58:27 AM
Metadata
Fields
Template:
Contract
Date
1/29/2020
Contract Starting Date
9/4/2019
Contract Ending Date
3/15/2020
Contract Document Type
Contract
Amount
$1,020.00
Document Relationships
R 2020-060 AMS - FESS Whitted sprinkler repair
(Attachment)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID:66lA1C8D-C699-4A66-B2D6-51BA5E14701B <br /> . T <br /> RALEIGH-DURI-!AM <br /> 1.11 hiternationai lkh'r <br /> FESS diOUTisl4le,NC27560 <br /> {a)919-469-81199 <br /> FIRE PROTECTION or8Ca3jFG,6040 <br /> Al('Stale License Ni nnber 25532 <br /> PAY M E N T THE ENTIRE AMOU NT OF CONTRACT TO 6E PAID WITHI N 30 DAYS AFTER COMPLETION. <br /> NOTE:THIS PROPOSAL MAY 6E WITHDRAWN 6Y US IF NDT ACCEPTED WITHIN 30 GAYS. <br /> AIL MATERIAL 45 GUARANTEED TO BE AS SPECIFIER ASL WORK TO BE COMPLETED IN A WORKMAN UKE AUTHORIZED <br /> MANNER MCORMNG TO STANDARD PRACTICES.ANY ALTERATION OR VKVATION FROM THE ABOVE <br /> SKOFICATION INWILM NG EMRA COSTS WILL BE EXECUTED ONLY UPON WFITTEN ORDERS,AND WILL <br /> BECOME AN EXTRA CNASGE OVER AND AEUV THE ESTIMATE.ALL AGREEMENTS COMINGE NT UPON SIGNATURE <br /> STRIKES,ACCIDENTS OR DELAYS BEYOND OUR CONTRA.OWNER TO CARRY FIRE,TORNADO AND OTHER <br /> NECESSARY IN SVRANCE,OUR WORKERS All E FULLY COVERED 8Y WORKM E N'S COMPEN5ATL4.4 I NSURANCE. Theresa Bailey <br /> IF PAYMENT FOR WORK PROVIDED IN THIS PROPOSAL IS NOT PAID WHEN OLB,WSTOMER AGREESTO PAY <br /> CO5FSOF COLLECTION INCLUDING ATTORNEYS FEES. Service Sales Rep <br /> PLEASE NOTE:RECOMMENDED NOTED ON THE INSPECTION REPORT WILL REQUIRE A SITE VISIT AND A SEPARATE <br /> PROPOSAL. <br /> ACCEPTANCE OF PROPOSAL <br /> THE ABOVE PRICE S SPECI FICAT[ONS AND CON DITIGNS ARE 5ATI$FACTORY AND A RE H E RE BY ACCE PT ED.YO U ARE AU THORIZED TO DO THE WORK A55PZFI FIED,PAYMENT <br /> WILL BE MADE AS OUTLINED ABOVE.E OF ACCEPTANCE SIGNATURE <br /> Additional proposed inspection services such as but not limited to Annual Fire Back ow Foi-ward Flaw 5-}'ear Infernal <br /> Irivesli atiaT 5-3 ear alarm valve obstruction investi alion 5-}ear II di•osialic test on FDC i itt 5-Year inlernal i�DC <br /> check valve ilas ection 5-)ear Stand pipe infernal pipe obstruction invesli atian 5-Year Sland i e F101V Test 3-Year air leak <br /> test 10 20 50- ear old are s rinkler head lest etc...Are required pei-local state and NFP.4-25 Code. Fess Fire Protection <br /> Inspectors make no recommendations for system improvements during an NFPA-25 inspection,only listing deficiencies that <br /> are currently required by code to be corrected to the best of his or her knowledge at the time of inspection.You may <br /> receive an addendum to the report,this is not be considered part of the NFPA-25 report <br /> Deficiencies Found During the Annual Fire Sprinkler Inspection 06/27/2019 <br /> Whitted Human Services Center Complex-300 West Tryon Street-Hillsborough NC 27278 <br /> BACKFLOWS <br /> 6"fire line backf low failed testing <br /> ALL SYSTEMS <br /> No 5-Year inspection tag found. <br /> No hydraulic data plates. <br /> Need hydrostatic test on FDC piping. <br /> Gauges are outdated. <br /> FDIC sign is faded,suggest replacement. <br /> 2ND FLOOR <br /> AT ROOM 230 LEFTOF EXIT:Painted sidewalI at room 230 <br /> IN ROOM 250 AT ENTRANCE:Loaded pendant <br /> SYSTEM 3 DRY <br /> No 3-Year air leak test tag found. <br /> Compressor did not want to cut off,was sending high air supervisory.May need switch replaced. <br /> a division ofCormmerciatServices,Inc.I FVTVTvfeSsinc.ne1 <br /> FIRE EXTINGUISHERS I SPRINKLER 1' SUPPRESS1014 <br /> CHARLOTTE • RALEIGH-DURHAM • WINSTON-SALEM • GREENSBOR❑ - CHARLESTON <br />
The URL can be used to link to this page
Your browser does not support the video tag.