Orange County NC Website
DocuSign Envelope ID:70BEFB46-21AF-468E-90A1-930CDF49F361 Tint:Quoteview:ServiceTrade V0 _VoK 10-3q`Fa <br /> From FESS Fire Protection <br /> v4TFESS <br /> 131 International Drive <br /> Morrisville NC 27560 <br /> (919)663-0400 <br /> www.fessfire.com <br /> FIRE PROTECTION <br /> Quote No. 1034524 Quote For Asset Management <br /> Type Inspection Repair Services Orange County <br /> Prepared By Theresa Bailey (Billing) <br /> Created On 12/24/2019 Orange County-Seymour <br /> Valid Until 01/31/2020 Center <br /> 2551 Homestead Road <br /> Gospel Hill NC 27516 <br /> (919)245-2625 <br /> Description of Work <br /> Allison, <br /> The link below will take you to the proposal for the deficiencies found during the annual fire sprinkler inspection. <br /> If you would like us to schedule this work, please click the green"APPROVE"button on the top right corner. <br /> If you have any questions,please feel free to tail me. <br /> Theresa <br /> Ali work listed on the proposal must be accepted and scheduled for the same date to maintain the proposal pricing. <br /> The owner/owner's representative shall place alarm systems on test and restore upon completion of work. <br /> EXCLUSIONS: <br /> 1. Any Additional Work NOT Specifically Listed in the proposal <br /> 2. Lift rental to perform the NFPA-25 code required internal pipe investigation and/or service work <br /> 3, No Draining of Low Point Drains Other Than At The Time of The Service <br /> 4. Over Time And/or After-Hours Costs Weekends And/or Holidays <br /> Sprinkler Service&Inspection Deficiencies <br /> FESS Fire Protection appreciates the opportunity to provide you with the following proposal to correct your fire sprinkler system <br /> deficiencies. All services will be completed by qualified personnel in accordance with NFPA 25. This proposal includes all materials, <br /> labor,and permits for the work listed.Additional work will be quoted separately upon request. <br /> All services are performed during normal work hours Monday through Friday 7:00 am to 5:00 pm (excluding holidays), unless otherwise <br /> agreed upon in advance. <br /> Services to be completed <br /> [Backflow] Backflow-WILKINS 375ADA 02637 HOT BOX-ALONG SIDE HOMESTEAD ROAD <br /> Need to adjust(2) System Sensors on the fire Backflow in the hot box by the street. <br /> Switches report to fire panel but need to be adjusted back in the OSY Stem groove. <br /> No material needed.- repair <br /> https:Napp.servicetrade.cornlquoteview/print?id=%2ByKpgcdaZJyich8ml yGIA4KtP2fdiYSshrhpuuxwrHlj9vhJvtDNpmkeYnz74on7wH4EJJtBsTxQHzv... 1/2 <br />