Browse
Search
2020-050-E AMS - FESS Seymour sprinkler repair
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2020
>
2020-050-E AMS - FESS Seymour sprinkler repair
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2020 9:14:01 AM
Creation date
1/28/2020 12:04:11 PM
Metadata
Fields
Template:
Contract
Date
1/29/2020
Contract Starting Date
1/29/2020
Contract Ending Date
3/15/2020
Contract Document Type
Contract
Amount
$1,392.13
Document Relationships
R 2020-050 AMS - FESS Seymour sprinkler repair
(Attachment)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID:70BEFB46-21AF-468E-90A1-930CDF49F361 <br /> . T RALEIGN-DURHAM <br /> FESS 131 klernalrwrailkhe <br /> hlwrisrilte,NC27500 <br /> (v)919-469-8099 <br /> FIRE PROTECTION ar800,150-6040 <br /> NC State License Number 25532 <br /> PLEASE NOTE: RECOMMENDED NOTED ON THE INSPECTION REPORT WILL REQUIRE A SITE VISIT AND A SEPARATE <br /> PROPOSAL. <br /> ACCEPTANCE OF PROPOSAL <br /> THE ABOVE PRICES SPECI FICATIO NS AND CON DITION 5 ARE SATs SFACTORY AND ARE H EREBY ACCEPTED.YOU ARE AU THORIZED TO DO TH E WOR K AS SPECIE I ED.PAYMENT <br /> WILL BE MADE AS OUTLINED ABOVE-E OF AM PTANCE SIGNATLIRE <br /> TITLE <br /> Additional proposed inspection services such as but not limited to Annual Fire Backfloir Forward r7ow, 5-}`ear Internal <br /> 1nvesligalion, 5-Year alarm valve obstruction inveslipation, 5-Year Hydrostatic lest on FDC pig?? , 5-)ear internal I'DC <br /> check valve iizs ection 5-}'ear Stand pipe internal pipe obstruction investi alias 5-Year Standpipe Flow Test 34 ear air leak <br /> test 10 20 50- ear old fire s rinkler liead test etc...Are required Per local stale and NFPA-25 Code. Fess Fire Protection <br /> Inspectors make no recommendations for system improvements during an NFPA-25 inspection,only fisting deficiencies that <br /> are currently required by code to be corrected to the best of his or her knowledge at the time of inspection.You may <br /> receive an addendum to the report,this is not be considered part of the NFPA-25 report. <br /> Deficiencies Found During the Annual Fire Sprinkler Inspection 06/27/2019 <br /> Orange County-Seymour Center-2551 Homestead Road-Chapel NC 27516 <br /> ALL SYSTEMS <br /> Data plates are illegible,none on main riser.(See Note Below) <br /> Need(1)head wrench for Tyco TY3531 concealed heads. <br /> No 5-Year inspection tag found. <br /> Gauges(2)are outdated,main riser anly(none for systems 1&2). <br /> SYSTEM 1 <br /> AT ROOM 104: Painted upright under stairs also has rusty nipple. (See Picture Below) <br /> AT ROOM 104: Upright under stairs also needs a head guard <br /> COOLER&FREEZER: Dry pendants in cooler and freezer(1 each)are over 10 years old,dated 2000. <br /> FREEZER: Dry pendant in freezer has bent damaged deflector. (see Picture Below) <br /> SYSTEM 2 <br /> AT ENTRANCE: Need(1)concealed plate adjusted <br /> RECEPTION DESK:(1)Painted white concealed plate <br /> BACKFLOW <br /> Need forward flow test,may need engineering survey because data plates are illegible.(See Note Below) <br /> a division of Commercial5ervices,Inc.I wlvwfessinc.net <br /> SUPPRESSIONFIRE EXTINGUISHERS I SPRINKLER I <br /> CHARLOTTE • RALEIGH-DURHAM • WINSTON-SALEM • GREENSBORO • CHARLESTON <br />
The URL can be used to link to this page
Your browser does not support the video tag.