Browse
Search
2019-920-E AMS - Hoffman Mechanical Solutions BOE HVAC repair
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2019
>
2019-920-E AMS - Hoffman Mechanical Solutions BOE HVAC repair
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2020 9:46:43 AM
Creation date
1/6/2020 9:29:54 AM
Metadata
Fields
Template:
Contract
Date
1/6/2020
Contract Starting Date
1/6/2020
Contract Ending Date
1/31/2021
Contract Document Type
Agreement - Services
Amount
$2,255.00
Document Relationships
R 2019-920 AMS - Hoffman Mechanical Solutions BOE HVAC repair
(Attachment)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2019
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> <br />Version 08262019 Page 5 of 9 <br /> <br />Equipment List <br />The following “Covered Equipment” will be serviced at: <br /> <br /> <br />Inspection Schedule: <br /> <br />Base Daikin VRV/VRF preventative maintenance service agreement: <br />x Outdoor Units. <br />o Investigate alarms. <br />o Verify proper power supply. <br />o Visually inspect electrical connections. <br />o Visually inspect for signs of refrigerant leaks. <br />o Visually inspect coil cleanliness. <br />o Verify temperature and pressure sensor calibration. <br />o Verify coil temperature control processes. <br />o Verify proper refrigerant level. <br />o Verify proper DIII communications. <br />o Record operating data. <br />x Indoor Units. <br />o Investigate alarms. <br />o Verify sensor calibration. <br />o Verify fan operation. <br />o Confirm start/stop command operation. <br />o Verify indoor unit response to temperature setpoint changes. <br />o Verify proper EEV control. <br />o Verify proper Branch Selector box mode control. <br />o Backup iTouch Manager/Controller database. (If equipped.) <br />Quantity Manuacturer Model No. Notes <br />1 Daikin REYQ120TATJU HR Outdoor Unit <br />1 Daikin REYQ72TATJU HR Outdoor Unit <br />1 Daikin RXYQ96TTJU HP Outdoor Unit <br />2 Daikin BS10Q54TVJ Multi-port Branch Selector <br />1 Daikin BS8Q54TVJ Multi-port Branch Selector <br />19 Daikin FXZQ07TAVJU Fan Coil <br />5 Daikin FXZQ12TAVJU Fan Coil <br />2 Daikin FXMQ30PBVJU Fan Coil <br />1 Daikin FXMQ96MFVJU Outdoor Air Processor <br />Orange County Board of Elections <br />All Associated Daikin Central and Zone Controls <br />Description Jan Feb Mar Apr May June July Aug Sept Oct Nov Dec <br />VRV Cooling Performance Evaluation X <br />VRV Heating Performance Evaluation X <br />VRV Outdoor Unit Coil Cleaning X <br />DocuSign Envelope ID: 4EBCEE15-C560-4E89-8C87-EA0F43F3CA6D
The URL can be used to link to this page
Your browser does not support the video tag.