Orange County NC Website
DocuSign Envelope ID:A18808EO-5F70-4494-BCOC-49B95D82162D <br /> Page 14 <br /> Each Item Detailed Specification <br /> equipped with recessed, paddle type latches and key <br /> operated locks. Latches and locks shall be stainless steel. <br /> 1 Undercoating, entire The entire underside of the body, including floor components, <br /> chassis sides and panels below floor level and exterior <br /> compartments, shall be coated with fire-resistant and rust <br /> resistant material composed of asphalt, rubber, or other <br /> approved material applied by spray method. <br /> 1 Video, rear view system High resolution rear vision system for wide field-of-view to <br /> with in-cab monitor facilitate backing and merging into traffic. On-screen distance <br /> grid to assist driver in judging distance. Camera must <br /> function in very bright to minimal ambient light, with field of <br /> view of 115 degrees horizontal and 84 degrees vertical. <br /> 1 Water heater, Tank-type water heater. No in-line heaters. <br /> undercounter <br /> 1 Water level monitoring Remote readings on digital instrument pad for water levels in <br /> system all tanks, in 10 percent increments. <br /> 1 Water tanks & pump, 55 Potable water pump to be self-priming, thermally protected, <br /> gal. ea. and include check valves rated to 200 psi to prevent cycling <br /> and backflow. Pump must run dry without damage for up to <br /> 200 hours. The water tanks shall be of proper capacity listed, <br /> with all internal plumbing lines to be rigid plastic pipe suitable <br /> for drinking water. All runs shall slope to low points to <br /> facilitate draining of the system. The runs shall be made in <br /> the sub-floor area to the maximum extent possible to <br /> minimize the risk of freezing. All other runs shall be freeze <br /> protected with a thermostatically controlled heating system. <br /> All drains shall be properly vented out to the side of the health <br /> van with louvered covers over the openings. The water <br /> supply system shall be designed and constructed to assure <br /> pure drinking water conforming to the following: National <br /> Sanitation Foundation International Standard 14 for <br /> ingredients, materials, products, quality assurance, and <br /> marking, National Sanitation Foundation International <br /> Standard 61 for taste, impurities and harmful chemicals in the <br /> system components. Freeze-stabile tubing shall be furnished <br /> to conduct water throughout the system. Tubing shall be in <br /> accordance with NSF, ASTM F876 and ASTM F877. All <br /> fittings shall comply with ASTM F877 and CSA B137.5. <br /> Tubing shall withstand freezing without leaking or breaking. <br /> Tubing shall have a rated working pressure of 100 psi at 180 <br /> degrees Fahrenheit. All tubing joints shall be easily <br /> accessible for repairs through access panels. The tubing <br /> shall be installed behind the finished walls or below the sub- <br /> floor. No visible tubing in public areas shall be permitted. All <br /> other tubing runs shall be protected with a thermostatically <br /> controlled freeze protection heating system with accessible <br /> test points for each circuit. All drain pipes shall be A.B.S or <br /> P.V.0 rigid plastic pipes. Drainage pipes shall be pitched for <br /> gravity flow to final disposal. All drain pipes shall be installed <br /> behind the finished walls or below the sub-floor. No visible <br /> pipes in public areas shall be permitted. Drain pipes shall be <br /> properly vented out to the side of the vehicle with louvered <br /> covers over the openings. Each plumbing fixture that has a <br /> drain shall be provided with a water trap. The water supply <br /> system shall be designed so that all contained water in the <br />