Orange County NC Website
DocuSign Envelope ID:A18808EO-5F70-4494-BCOC-49B95D82162D <br /> Page 13 <br /> Each Item Detailed Specification <br /> National Electrical Code. The wire gauge shall provide for a <br /> rating of 80 amperes minimum. The electrical panel in the <br /> health van shall be provided with an access door, latch and <br /> key lock and sized to contain the power cable. <br /> 1 Shore power, aluminum A rewind reel to handle live electric cable shall be equipped <br /> reel & box with four-way roller assembly, large bending radius, and non- <br /> sparking ratchet assembly to lock the reel when the desired <br /> length of cable has been played out. A 100 amp 4-conductor <br /> collector assembly with wiring from the collector ring to the <br /> junction box. Brushes to be copper graphite with copper alloy <br /> rings. A cable stop shall be used to prevent damage to rollers <br /> and connectors and to permit adjustment of free cable length. <br /> 1 Shore power cord Extension with male and female receptacle at either end. <br /> extension, 25 feet Allows further extension of building receptacle. <br /> 2 Smoke detector, battery Provide battery operated DC voltage smoke alarm(s) so that <br /> vehicle is protected if electricity fails, provided the batteries <br /> are fresh and correctly installed. Unit to emit an 85 decibel <br /> alarm for an early warning of fire. <br /> 1 Stairs, entry, manual Solid aluminum construction, with diamond plate stair treads <br /> with static coefficient of friction (COF) 0.70 wet and 0.80 dry. <br /> Tread surface to surpass ADA, NFPA, and OSHA <br /> requirements. No r.v. electric step systems allowed. Each <br /> stairway shall be constructed using aluminum channels and <br /> aluminum I-beam stringers to form the frame. The frame <br /> components shall be welded or bolted. The width of each <br /> stairway shall be a minimum of 33 inches. The stairway tread <br /> depth shall be 8 inches, plus or minus 1 inch. The stairway <br /> riser height shall be 8 inches, plus or minus 1 inch. The <br /> construction of the stairway shall be without riser panels. A <br /> portable step stand shall be furnished to mitigate against an <br /> non-uniform riser height between the bottom stairway step <br /> and the ground. Each step stand shall be min. 11 inches <br /> wide x 33 inches long x 3 inches (+/-1 in.) high from ground. <br /> Each step stand shall be capable of supporting 500 pounds <br /> without permanent deformation or breakage. The top of the <br /> step stand shall have a matching aluminum diamond plate <br /> surface. The weight of each step stand shall not exceed 15 <br /> pounds. <br /> 1 Stairs, handrail storage Solid aluminum construction with diamond plate door and <br /> compartment locking system. Storage compartment to contain stair system <br /> handrail while in transit. The components of the compartment <br /> shall be welded or bolted. <br /> 1 Stairs, high-traction tread Step covers are fit over existing steps. Slightly rounded for <br /> covers snug fit on Bull Nose leading edges of stairs. Doubles <br /> OSHA's 0.5 guideline and exceeds ADA's 0.6 measure for <br /> Coefficient of Friction values. Exceeds guidelines even in wet <br /> or oily conditions. <br /> 1 Storage compartment, Individual 3/16 in. thick diamond plate aluminum doors on the <br /> undercarriage curbside and streetside of the vehicle shall be furnished to <br /> provide access to holding tanks and equipment. The doors <br /> shall be hinged at the top. Means shall be provided to <br /> positively retain the doors in the open position. Doors shall <br /> be provided with replaceable weather seals to protect <br /> materials stored inside from weather. Each door shall be <br />