29 <br /> SCHEDULE A <br /> SPECIFICATIONS <br /> Each Item Detailed Specification <br /> tile flooring alkali, grease, ands ills. <br /> 1 Freight&delivery Unit must be delivered to Department location, FOB <br /> charges <br /> 2 Generator, compartment Undercarriage compartment with generator mounted on high <br /> capacity slides for easy pull out maintenance or replacement. <br /> Sound isolation and rear and underside ventilation provided. <br /> Operation capable while in transit. Rear cabin sound levels <br /> less than 60db. <br /> 2 Generator, diesel, 20 kw A 20 kilowatt, 60 Hertz, single phase, 120/240 volt diesel <br /> generator shall be furnished. Generator to be mounted <br /> outside the rear cabin work area. Hour meter and remote start <br /> switch must be provided. The generator frame shall be <br /> mounted on a second set of approved isolators to minimize <br /> noise and vibration into the body. A remote generator control <br /> start-stop switch shall be provided in the clinic interior. At the <br /> generator will be a start/stop switch, pre-heater, and hour <br /> meter. The generator shall have an easily accessible oil <br /> drain, and be capable of being serviced from the exterior side <br /> of the compartment. The exhaust shall be ported and angled <br /> to the rear street-side away from the clinic area. Noise level <br /> with maximum load is to be 68 dBA or lower inside vehicle. <br /> 2 Generator, vibration Diesel generator to be sound-proofed with completely <br /> reduction system enclosed housing and vibration-reducing system with proper <br /> ventilation. The generator enclosure shall have continuous <br /> acoustic, non-water-holding, self-extinguishing insulation <br /> installed. The door louver opening design shall allow the full <br /> amount of cooling air required by the generator without <br /> exceeding the maximum static pressure. The enclosure and <br /> door shall be dimensioned to provide full access to the <br /> generator for servicing and ventilation. Louvers shall be <br /> angled to minimize the entrance of road splash and debris. <br /> Lockable latch door shall provide access to the generator. A <br /> louvered grille with screen shall be furnished to prevent <br /> foreign objects from entering the engine. <br /> 1 Graphics, exterior, Department personnel to select a graphics package for the <br /> custom vinyl exterior of the van using 3M or Avery Dennison exterior grade <br /> vinyls. Body decor is to be rendered in a combination of <br /> Percentage of rear cabin premium exterior grade vinyl and/or paint. Four-color process <br /> coverage: printed vinyl is to be 3M Controltac Plus Graphic Film <br /> w/Comply Performance, number 180C. All printed vinyl must <br /> 100% coverage be coated with 3M Scotchcal luster-finish overlaminate to <br /> provide outdoor graphics with protection against the elements, <br /> including UV rays. Solid color vinyl, if used, is to be vinyl film <br /> Percentage of cab that is 2.0 mil opaque high-gloss high-performance cast film <br /> coverage (zero percent with 1.0 mil acrylic adhesive with liner of 78 lb. white bleached <br /> if cab accents only): kraft. Some large color block areas of the design may be <br /> rendered onto the properly-prepared body sheathing in <br /> 100% coverage automotive paint that is a fast-drying single stage <br /> polyurethane finish designed suitable for vehicle refinishing. <br /> Various preparation chemicals, such as hardeners and dry <br /> additives, can be used to prepare and cure the paint to a <br /> gloss finish. Allowance amount is an estimate, which may <br /> vary when actual graphics package is approved by owner. <br /> Exact lettering, size and layout shall be provided to the <br /> contractor within 30 days after award of the contract. <br />