Browse
Search
2019-640-E AMS - Siemens Building Technologies ES HVAC controls
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2019
>
2019-640-E AMS - Siemens Building Technologies ES HVAC controls
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2019 9:00:10 AM
Creation date
9/19/2019 8:48:03 AM
Metadata
Fields
Template:
Contract
Date
9/16/2019
Contract Starting Date
9/16/2019
Contract Ending Date
1/30/2020
Contract Document Type
Agreement - Construction
Amount
$39,125.00
Document Relationships
R 2019-640 AMS - Siemens Building Technologies ES HVAC controls
(Attachment)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2019
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID:299C1 D9F-FB2B-45B9-AA1 F-9C3418D1287B <br /> Jake Snyder <br /> Sales Executive SIEMENS <br /> 215 Southport Dr,Suite 900 <br /> Morrisville,NC 27560 Building Technologies <br /> Mobile: (919)413-1666 <br /> Email:jacob.snyder@siemens.com <br /> General Scope Items <br /> • Includes the following provisions for the renovation; <br /> 1. Provide One(1)year warranty for workmanship and parts <br /> 2. Payment Terms per the specifications <br /> 3. Project management <br /> VRF System <br /> • Furnish and install the following as noted in the below scope with the following clarification and/or <br /> exceptions; <br /> 1. Integrate to VRF system via one(1)existing Mitsubishi AE-200A Master Controller. Ethernet <br /> drop and connection to the AE-200A by Orange County. <br /> 2. Provide BACnet integration to allow visibility and control functionality of the VRF system to <br /> include(43)indoor head-end units. <br /> 3. Create and install Desigo CC BMS graphics to represent the VRF system and each of the(43) <br /> indoor units. <br /> 4. Checkout the VRF system integration for proper functionality. <br /> Heat Pumps-(3)and Exhaust Fan <br /> • Furnish and install the following as noted in the below scope with the following clarification and/or <br /> exceptions; <br /> 1. Provide and install Siemens PXCC panel and enclosure for Field Level Network(FLN). <br /> 2. Provide and install Siemens controller and sensors for(3) Heat Pumps. <br /> 3. Run FLN wiring trunk from PXCC to(3)Heat Pump controllers. <br /> 4. Create and install Desigo CC BMS graphics for all(3)Heat Pumps. <br /> 5. Perform standard startup and checkout of new PXC panel and Heat Pump controllers. <br /> 6. Provide and install relay and current switch for(1)exhaust fan. <br /> 7. Create and implement programing for(1)exhaust fan. <br /> AAON Unit <br /> • Furnish and install the following as noted in the below scope with the following clarification and/or <br /> exceptions; <br /> 1. Run BACnet MS/TP truck from PXCC panel to existing AAON DOAS unit. <br /> 2. Provide BACnet integration to allow visibility and control functionality of the AAON DOAS unit. <br /> 3. Create and install Desigo CC BMS graphic to represent the AAON DOAS unit. <br /> 4. Checkout the AAON DOAS system integration for proper functionality. <br /> Page 2 of 7 <br /> Initials <br />
The URL can be used to link to this page