Orange County NC Website
<br />Jake Snyder <br />Sales Executive <br />215 Southport Dr, Suite 900 <br />Morrisville, NC 27560 <br />Mobile: (919) 413-1666 <br />Email: jacob.snyder@siemens.com <br /> <br />Page 2 of 7 <br />Initials ______ <br /> <br /> <br />General Scope Items <br /> Includes the following provisions for the renovation; <br />1. Provide One (1) year warranty for workmanship and parts <br />2. Payment Terms per the specifications <br />3. Project management <br /> <br /> <br />MEC/FLNC Migration <br /> Furnish and install the following as noted in the below scope with the following clarification and/or <br />exceptions; <br />1. Before any work shall commence, we will notate any failed points or points in override and bring <br />this to the customers attention <br />2. Label all existing wiring in existing MEC panel <br />3. Remove existing MEC electronic board components and modules <br />4. Provide and install one PXC conversation kit with backplane in existing MEC cabinet <br />5. Provide and install PXC series controller along with necessary expansion modules in existing MEC <br />cabinet <br />6. Convert existing programming in MEC over to new PXC modular <br />7. Perform standard startup and checkout of new PXC panel as well as expansion modules to ensure <br />conversion process was completed successfully <br />8. Perform a point to point verification to ensure all points are reading correctly and operating <br />correctly <br />9. The following obsolete controllers will be migrated according to this scope: <br /> Animal Services, MEC 01 <br /> Controls: Hot Water System (2 x Boilers, 3 x Pumps, Temps, DPs) <br /> Animal Services, MEC 02 <br /> Controls: Exhaust Fans, Fan Coil Units, VAVs <br /> Justice, MEC 04 <br /> Controls: Geothermal (Pumps/VFDs, Water Temps, Outside Temp/Hum, RM <br />Temps), Electric Meter, Water Meter, Air Handler Emergency Stop, Heap <br />Pumps, Domestic HW, Heat Recovery Unit 1 <br /> Whitted, MEC Node 02 <br /> Controls: Air Handler 1B, Space CO2, Ground and 1st Floor VAVs <br /> Whitted, MEC Node 03 <br /> Controls: Air Handler 1G & 2G, Space Temps, Gym CO2, AHU 1-4 <br /> Whitted, FLNC Node 04 <br /> Controls: Ground and 1st Floor TECs <br /> <br /> <br />Insight to Desigo CC Migration <br /> Furnish and install the following as noted in the below scope with the following clarification and/or <br />exceptions; <br />1. New computer and peripheral devices provided by Orange County <br />2. Desigo CC software installed on new computer <br /> Includes all licensing at the Preferred Customer pricing level for being an active Siemens <br />customer (best pricing available) <br />3. Insight database migrated to Desigo CC <br />4. Connect existing field panel/controller and FLN networks to Desigo CC <br />5. Add existing user accounts to Desigo CC <br />6. Determine existing and used trends, reports, and graphics and migrate to Desigo CC <br />7. Graphics will be upgraded using vector formatting and enhanced functionality. <br />8. Includes (4) hours of onsite training <br />DocuSign Envelope ID: 15027EFD-227A-4F40-AC0E-22DDC9A9A2B9