Browse
Search
2010-171 AMS - Owens Roofing DA and Annex
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2010
>
2010-171 AMS - Owens Roofing DA and Annex
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/8/2019 3:34:51 PM
Creation date
7/3/2019 11:41:50 AM
Metadata
Fields
Template:
Contract
Date
12/3/2010
Contract Starting Date
12/3/2010
Contract Ending Date
1/2/2011
Contract Document Type
Agreement - Construction
Amount
$90,591.00
Document Relationships
R 2010-171 AMS - Owens Roofing DA and Annex
(Attachment)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2010
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
129
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Prebid Minutes <br /> Government Services Annex <br /> District Attorney Office <br /> September 21 , 2010 <br /> Page 4 <br /> Parking and site access will be as directed by the Owner . <br /> Section 015639 — Tree and Plant Protection <br /> Site is to be restored to original condition upon completion of work . <br /> Section 016000 — Material and Equipment <br /> No comment . <br /> Section 017700 — Project Close-out Procedures <br /> All closeout documents to include but not necessarily limited to warranties, as -built drawings, final <br /> itemized pay request, etc . to be submitted . All documents to be submitted simultaneously so as not <br /> to delay release of retainage and project close out . <br /> Section 017710 — Cleaning <br /> No Comment <br /> Section 017839 — Project Record Documents <br /> No Comment . <br /> Section 017850 — Warranties <br /> 5 -year contractor warranty required . <br /> 40-year manufacturer warranty required . <br /> VIII. TECHNICAL SPECIFICATIONS <br /> 024119 - Selective Demolition <br /> All existing roofing materials including shingles , underlayment, flashing, sheet metal (gutter, <br /> downspout, counterflashing, drip flashing, miscellaneous trim , static gravity vents , etc . to be <br /> removed . <br /> 061000 - Rough Carpentry <br /> Close in deck openings e . g . locations where static gravity vents have been removed . Remove and <br /> replace deteriorated or damaged wood to include deck, nailers , blocking, etc . <br /> 073113 - Asphalt Fiberglass Shingles <br /> Ice shield to be installed at eaves , valleys , hips , ridges , penetrations . <br /> 40 -year asphalt fiberglass shingles to be installed . <br /> 076200 - Sheet Metal Flashing and Trim <br /> All sheet metal to be copper . <br /> 079200 - Sealants and Caulking <br /> No comments . <br />
The URL can be used to link to this page
Your browser does not support the video tag.