Browse
Search
2010-171 AMS - Owens Roofing DA and Annex
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2010
>
2010-171 AMS - Owens Roofing DA and Annex
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/8/2019 3:34:51 PM
Creation date
7/3/2019 11:41:50 AM
Metadata
Fields
Template:
Contract
Date
12/3/2010
Contract Starting Date
12/3/2010
Contract Ending Date
1/2/2011
Contract Document Type
Agreement - Construction
Amount
$90,591.00
Document Relationships
R 2010-171 AMS - Owens Roofing DA and Annex
(Attachment)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2010
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
129
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5thWall Building Diagnostics Consultants Government Services Annex <br /> District Attorney Office <br /> Roof Replacement <br /> November 2009 <br /> H . Nailers shall be grooved for edge venting $ install at walls , curbs , and other vertical <br /> surfaces with a '/4-inch gap between each length . <br /> I . New wood nailers , blocking, etc . , shall be chamfered , beveled , shaved , planed , or <br /> shimmed as necessary to provide smooth transition to adjacent materials . <br /> J . Install new wood blocking to facilitate not less than 8 inches of vertical flashing above <br /> adjacent finished roof surface . <br /> K . Existing nailers remaining in place shall be firmly anchored in accordance with <br /> paragraph 3 . 02 . 1) and shall be free of rot, excess moisture and deterioration . <br /> L . Where new wood curbs are to be installed, corners shall be formed by lapping side <br /> members alternately . <br /> 3 . 03 Installation - Plywood <br /> A . Plywood shall be installed where indicated on the drawings . Plywood shall be secured <br /> with a minimum of two fasteners or one fastener every two square feet whichever is <br /> greater . Fasteners shall be located 2 inches from the top and bottom edges . <br /> Be Top of plywood shall be beveled at 45 degrees . <br /> END OF SECTION <br /> 09 -26 Rough Carpentry <br /> 061000 -4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.