Browse
Search
2019-193-E AMS - Sasser Companies ES remediation
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2019
>
2019-193-E AMS - Sasser Companies ES remediation
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2019 9:07:31 AM
Creation date
3/29/2019 9:19:27 AM
Metadata
Fields
Template:
Contract
Date
3/20/2019
Contract Starting Date
3/20/2019
Contract Ending Date
8/8/2019
Contract Document Type
Agreement - Construction
Agenda Item
3/19/19; 8-i
Amount
$1,499,409.00
Document Relationships
2019-408-E AMS - Sasser Change Request 1 drywall removal
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-480-E AMS - Sasser Companies mechanical system replacement contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-778-E AMS - Sasser Companies Inc ES remediation amendment 3
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-918-E AMS - Sasser ES Change Request 4
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2020-068-E AMS - Sasser Companies ES panel install contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2020's\2020
Agenda - 03-19-2019 8-i - Approval of a Construction Contract for the Remediation, Repair, and Reconstruction of the Phillip Nick Waters Emergency Services Building
(Attachment)
Path:
\Board of County Commissioners\BOCC Agendas\2010's\2019\Agenda - 03-19-19 Regular Meeting
R 2019-193 AMS - Sasser Companies ES remediation
(Attachment)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2019
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
557
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: B94F2D40-3B3C-47A7-86C2-6F1 B4F92C62C <br /> Orange County Emergency Services Building Construction Documents <br /> SECTION 26 05 33.16 <br /> BOXES FOR ELECTRICAL SYSTEMS <br /> PART 2 PRODUCTS <br /> 1.01 BOXES <br /> A. General Requirements: <br /> 1. Do not use boxes and associated accessories for applications other than as permitted by <br /> NFPA 70 and product listing. <br /> 2. Provide all boxes, fittings, supports, and accessories required for a complete raceway system <br /> and to accommodate devices and equipment to be installed. <br /> 3. Provide products listed, classified, and labeled as suitable for the purpose intended. <br /> 4. Where box size is not indicated, size to comply with NFPA 70 but not less than applicable <br /> minimum size requirements specified. <br /> 5. Provide grounding terminals within boxes where equipment grounding conductors terminate. <br /> B. Outlet and Device Boxes Up to 100 cubic inches, Including Those Used as Junction and Pull <br /> Boxes: <br /> 1. Use sheet-steel boxes for dry locations unless otherwise indicated or required. <br /> 2. Use cast iron boxes or cast aluminum boxes for damp or wet locations unless otherwise <br /> indicated or required; furnish with compatible weatherproof gasketed covers. <br /> 3. Use suitable concrete type boxes where flush-mounted in concrete. <br /> 4. Use suitable masonry type boxes where flush-mounted in masonry walls. <br /> 5. Use raised covers suitable for the type of wall construction and device configuration where <br /> required. <br /> 6. Use shallow boxes where required by the type of wall construction. <br /> 7. Do not use "through-wall' boxes designed for access from both sides of wall. <br /> 8. Sheet-Steel Boxes: Comply with NEMA OS 1, and list and label as complying with UL 514A. <br /> 9. Cast Metal Boxes: Comply with NEMA FB 1, and list and label as complying with UL 514A; <br /> furnish with threaded hubs. <br /> 10. Boxes for Supporting Luminaires and Ceiling Fans: Listed as suitable for the type and weight <br /> of load to be supported; furnished with fixture stud to accommodate mounting of luminaire <br /> where required. <br /> 11. Boxes for Ganged Devices: Use multigang boxes of single-piece construction. Do not use <br /> field-connected gangable boxes unless specifically indicated or permitted. <br /> 12. Wall Plates: Comply with Section 26 27 26. <br /> C. Cabinets and Enclosures, Including Junction and Pull Boxes Larger Than 100 cubic inches: <br /> 1. Comply with NEMA 250, and list and label as complying with UL 50 and UL 50E, or UL 508A. <br /> 2. NEMA 250 Environment Type, Unless Otherwise Indicated: <br /> 3. Junction and Pull Boxes Larger Than 100 cubic inches: <br /> a. Provide screw-cover or hinged-cover enclosures unless otherwise indicated. <br /> END OF SECTION 26 05 33.16 <br /> PDC Project 18102 BOXES FOR ELECTRICAL 26 05 33.16- 1 <br /> 12/17/2018 SYSTEMS <br />
The URL can be used to link to this page
Your browser does not support the video tag.