2019-193-E AMS - Sasser Companies ES remediation
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2019
>
2019-193-E AMS - Sasser Companies ES remediation
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2019 9:07:31 AM
Creation date
3/29/2019 9:19:27 AM
Metadata
Fields
Template:
Contract
Date
3/20/2019
Contract Starting Date
3/20/2019
Contract Ending Date
8/8/2019
Contract Document Type
Agreement - Construction
Agenda Item
3/19/19; 8-i
Amount
$1,499,409.00
Document Relationships
2019-408-E AMS - Sasser Change Request 1 drywall removal
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-480-E AMS - Sasser Companies mechanical system replacement contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-778-E AMS - Sasser Companies Inc ES remediation amendment 3
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-918-E AMS - Sasser ES Change Request 4
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2020-068-E AMS - Sasser Companies ES panel install contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2020's\2020
Agenda - 03-19-2019 8-i - Approval of a Construction Contract for the Remediation, Repair, and Reconstruction of the Phillip Nick Waters Emergency Services Building
(Attachment)
Path:
\Board of County Commissioners\BOCC Agendas\2010's\2019\Agenda - 03-19-19 Regular Meeting
R 2019-193 AMS - Sasser Companies ES remediation
(Attachment)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2019
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
557
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: B94F2D40-3B3C-47A7-86C2-6F1 B4F92C62C <br /> Orange County Emergency Services Building Construction Documents <br /> 2.04 INTERMEDIATE METAL CONDUIT (IMC) <br /> A. Manufacturers: <br /> 1. Allied Tube& Conduit: www.alliedeg.com/#sle. <br /> 2. Republic Conduit: www.republic-conduit.com/#sle. <br /> 3. Wheatland Tube Company: www.wheatland.com/#sle. <br /> B. Description: NFPA 70, Type IMC galvanized steel intermediate metal conduit complying with ANSI <br /> C80.6 and listed and labeled as complying with UL 1242. <br /> 2.05 ELECTRICAL METALLIC TUBING (EMT) <br /> A. Manufacturers: <br /> 1. Allied Tube &Conduit; www.alliedeg.com/#sle. <br /> 2. Republic Conduit: www.republic-conduit.com/#sle. <br /> 3. Wheatland Tube Company; : www.wheatland.com/#sle. <br /> B. Description: NFPA 70, Type EMT steel electrical metallic tubing complying with ANSI C80.3 and <br /> listed and labeled as complying with UL 797. <br /> C. Fittings: <br /> 1. Manufacturers: <br /> a. Bridgeport Fittings Inc: www.bptfittings.com/#sle. <br /> b. O-Z/Gedney, a brand of Emerson Electric Co: www.emerson.com/#sle. <br /> c. Thomas & Betts Corporation: www.tnb.com/#sle. <br /> 2. Description: Fittings complying with NEMA FB 1 and listed and labeled as complying with UL <br /> 514B. <br /> 3. Material: Use steel or malleable iron. <br /> a. Do not use die cast zinc fittings. <br /> 4. Connectors and Couplings: Use compression (gland) or set-screw type. <br /> a. Do not use indenter type connectors and couplings. <br /> 2.06 RIGID POLYVINYL CHLORIDE (PVC) CONDUIT <br /> A. Manufacturers: <br /> 1. Cantex Inc: www.cantexinc.com/#sle. <br /> 2. Carlon, a brand of Thomas & Betts Corporation: www.carlon.com/#sle. <br /> 3. JM Eagle: www.jmeagle.com/#sle. <br /> B. Description: NFPA 70, Type PVC rigid polyvinyl chloride conduit complying with NEMA TC 2 and <br /> listed and labeled as complying with UL 651; Schedule 40 unless otherwise indicated, Schedule 80 <br /> where subject to physical damage; rated for use with conductors rated 90 degrees C. <br /> C. Fittings: <br /> 1. Manufacturer: Same as manufacturer of conduit to be connected. <br /> 2. Description: Fittings complying with NEMA TC 3 and listed and labeled as complying with UL <br /> 651; material to match conduit. <br /> 2.07 ACCESSORIES <br /> A. Corrosion Protection Tape: PVC-based, minimum thickness of 20 mil. <br /> B. Conduit Joint Compound: Corrosion-resistant, electrically conductive; suitable for use with the <br /> conduit to be installed. <br /> C. Solvent Cement for PVC Conduit and Fittings: As recommended by manufacturer of conduit and <br /> fittings to be installed. <br /> D. Pull Strings: Use nylon cord with average breaking strength of not less than 200 pound-force. <br /> PART 3 EXECUTION <br /> 3.01 EXAMINATION <br /> A. Verify that field measurements are as indicated. <br /> B. Verify that mounting surfaces are ready to receive conduits. <br /> C. Verify that conditions are satisfactory for installation prior to starting work. <br /> PDC Project 18102 CONDUIT FOR ELECTRICAL 26 05 33.13 - 3 <br /> 12/17/2018 SYSTEMS <br />
The URL can be used to link to this page
Your browser does not support the video tag.