Browse
Search
2019-193-E AMS - Sasser Companies ES remediation
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2019
>
2019-193-E AMS - Sasser Companies ES remediation
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2019 9:07:31 AM
Creation date
3/29/2019 9:19:27 AM
Metadata
Fields
Template:
Contract
Date
3/20/2019
Contract Starting Date
3/20/2019
Contract Ending Date
8/8/2019
Contract Document Type
Agreement - Construction
Agenda Item
3/19/19; 8-i
Amount
$1,499,409.00
Document Relationships
2019-408-E AMS - Sasser Change Request 1 drywall removal
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-480-E AMS - Sasser Companies mechanical system replacement contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-778-E AMS - Sasser Companies Inc ES remediation amendment 3
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-918-E AMS - Sasser ES Change Request 4
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2020-068-E AMS - Sasser Companies ES panel install contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2020's\2020
Agenda - 03-19-2019 8-i - Approval of a Construction Contract for the Remediation, Repair, and Reconstruction of the Phillip Nick Waters Emergency Services Building
(Attachment)
Path:
\Board of County Commissioners\BOCC Agendas\2010's\2019\Agenda - 03-19-19 Regular Meeting
R 2019-193 AMS - Sasser Companies ES remediation
(Attachment)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2019
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
557
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: B94F2D40-3B3C-47A7-86C2-6F1 B4F92C62C <br /> Orange County Emergency Services Building Construction Documents <br /> 4. Coordinate the work with other trades to provide roof penetrations that preserve the integrity <br /> of the roofing system and do not void the roof warranty. <br /> 5. Notify Architect of any conflicts with or deviations from the contract documents. Obtain <br /> direction before proceeding with work. <br /> B. Sequencing: <br /> 1. Do not begin installation of conductors and cables until installation of conduit is complete <br /> between outlet,junction and splicing points. <br /> 1.05 SUBMITTALS <br /> A. Product Data: Provide manufacturer's standard catalog pages and data sheets for conduits and <br /> fittings. <br /> 1.06 QUALITY ASSURANCE <br /> A. Conform to requirements of NFPA 70. <br /> B. Product Listing Organization Qualifications: An organization recognized by OSHA as a Nationally <br /> Recognized Testing Laboratory(NRTL) and acceptable to authorities having jurisdiction. <br /> 1.07 DELIVERY, STORAGE,AND HANDLING <br /> A. Receive, inspect, handle, and store conduit and fittings in accordance with manufacturer's <br /> instructions. <br /> PART 2 PRODUCTS <br /> 2.01 CONDUIT APPLICATIONS <br /> A. Do not use conduit and associated fittings for applications other than as permitted by NFPA 70 and <br /> product listing. <br /> B. Unless otherwise indicated and where not otherwise restricted, use the conduit types indicated for <br /> the specified applications. Where more than one listed application applies, comply with the most <br /> restrictive requirements. Where conduit type for a particular application is not specified, use <br /> galvanized steel rigid metal conduit. <br /> 2.02 CONDUIT REQUIREMENTS <br /> A. Fittings for Grounding and Bonding: Also comply with Section 26 05 26. <br /> B. Provide all conduit, fittings, supports, and accessories required for a complete raceway system. <br /> C. Provide products listed, classified, and labeled as suitable for the purpose intended. <br /> D. Where conduit size is not indicated, size to comply with NFPA 70 but not less than applicable <br /> minimum size requirements specified. <br /> 2.03 GALVANIZED STEEL RIGID METAL CONDUIT (RMC) <br /> A. Manufacturers: <br /> 1. Allied Tube& Conduit: www.alliedeg.com/#sle. <br /> 2. Republic Conduit: www.republic-conduit.com/#sle. <br /> 3. Wheatland Tube Company: www.wheatland.com/#sle. <br /> B. Description: NFPA 70, Type RMC galvanized steel rigid metal conduit complying with ANSI C80.1 <br /> and listed and labeled as complying with UL 6. <br /> C. Fittings: <br /> 1. Manufacturers: <br /> a. Bridgeport Fittings Inc: www.bptfittings.com/#sle. <br /> b. O-Z/Gedney, a brand of Emerson Electric Co: www.emerson.com/#sle. <br /> 2. Non-Hazardous Locations: Use fittings complying with NEMA FB 1 and listed and labeled as <br /> complying with UL 514B. <br /> 3. Hazardous (Classified) Locations: Use fittings listed and labeled as complying with UL 1203 <br /> for the classification of the installed location. <br /> 4. Material: Use steel or malleable iron. <br /> a. Do not use die cast zinc fittings. <br /> 5. Connectors and Couplings: Use threaded type fittings only. Threadless set screw and <br /> compression (gland)type fittings are not permitted. <br /> PDC Project 18102 CONDUIT FOR ELECTRICAL 26 05 33.13 - 2 <br /> 12/17/2018 SYSTEMS <br />
The URL can be used to link to this page
Your browser does not support the video tag.