Browse
Search
2019-193-E AMS - Sasser Companies ES remediation
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2019
>
2019-193-E AMS - Sasser Companies ES remediation
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2019 9:07:31 AM
Creation date
3/29/2019 9:19:27 AM
Metadata
Fields
Template:
Contract
Date
3/20/2019
Contract Starting Date
3/20/2019
Contract Ending Date
8/8/2019
Contract Document Type
Agreement - Construction
Agenda Item
3/19/19; 8-i
Amount
$1,499,409.00
Document Relationships
2019-408-E AMS - Sasser Change Request 1 drywall removal
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-480-E AMS - Sasser Companies mechanical system replacement contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-778-E AMS - Sasser Companies Inc ES remediation amendment 3
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-918-E AMS - Sasser ES Change Request 4
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2020-068-E AMS - Sasser Companies ES panel install contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2020's\2020
Agenda - 03-19-2019 8-i - Approval of a Construction Contract for the Remediation, Repair, and Reconstruction of the Phillip Nick Waters Emergency Services Building
(Attachment)
Path:
\Board of County Commissioners\BOCC Agendas\2010's\2019\Agenda - 03-19-19 Regular Meeting
R 2019-193 AMS - Sasser Companies ES remediation
(Attachment)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2019
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
557
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: B94F2D40-3B3C-47A7-86C2-6F1 B4F92C62C <br /> Orange County Emergency Services Building Construction Documents <br /> F. Comply with NEMA WC 70. <br /> G. Thermoplastic-Insulated Conductors and Cables: Listed and labeled as complying with UL 83. <br /> H. Thermoset-Insulated Conductors and Cables: Listed and labeled as complying with UL 44. <br /> I. Conductors for Grounding and Bonding: Also comply with Section 26 05 26. <br /> J. Conductor Material: <br /> 1. Provide copper conductors only. Aluminum conductors are not acceptable for this project. <br /> Conductor sizes indicated are based on copper. <br /> 2. Copper Conductors: Soft drawn annealed, 98 percent conductivity, uncoated copper <br /> conductors complying with ASTM B3, ASTM B8, or ASTM B787/13787M unless otherwise <br /> indicated. <br /> 3. Tinned Copper Conductors: Comply with ASTM B33. <br /> K. Minimum Conductor Size: <br /> 1. Branch Circuits: 12 AWG. <br /> a. Exceptions: <br /> 1) 20 A, 120 V circuits longer than 75 feet: 10 AWG, for voltage drop. <br /> 2) 20 A, 120 V circuits longer than 150 feet: 8 AWG, for voltage drop. <br /> 2. Control Circuits: 14 AWG. <br /> L. Conductor Color Coding: <br /> 1. Color code conductors as indicated unless otherwise required by the authority having <br /> jurisdiction. Maintain consistent color coding throughout project. <br /> 2. Color Coding Method: Integrally colored insulation. <br /> 3. Color Code: <br /> a. 480Y/277 V, 3 Phase, 4 Wire System: <br /> 1) Phase A: Brown. <br /> 2) Phase B: Orange. <br /> 3) Phase C: Yellow. <br /> 4) Neutral/Grounded: Gray. <br /> b. 208Y/120 V, 3 Phase, 4 Wire System: <br /> 1) Phase A: Black. <br /> 2) Phase B: Red. <br /> 3) Phase C: Blue. <br /> 4) Neutral/Grounded: White. <br /> c. Equipment Ground, All Systems: Green. <br /> 2.03 SINGLE CONDUCTOR BUILDING WIRE <br /> A. Manufacturers: <br /> 1. Copper Building Wire: <br /> a. Cerro Wire LLC: www.cerrowire.com/#sle. <br /> b. Encore Wire Corporation: www.encorewire.com/#sle. <br /> c. General Cable Technologies Corporation; : www.generaIcable.com/#sle. <br /> d. Southwire Company: www.southwire.com/#sle. <br /> B. Description: Single conductor insulated wire. <br /> C. Conductor Stranding: <br /> 1. Feeders and Branch Circuits: <br /> a. Size 10 AWG and Smaller: Solid. <br /> b. Size 8 AWG and Larger: Stranded. <br /> D. Insulation Voltage Rating: 600 V. <br /> E. Insulation: <br /> 1. Copper Building Wire: Type THHN/THWN or THHN/THWN-2, except as indicated below. <br /> a. Size 4 AWG and Larger: Type XHHW-2. <br /> b. Installed Underground: Type XHHW-2. <br /> PDC Project 18102 LOW-VOLTAGE ELECTRICAL 26 05 19- 3 <br /> 12/17/2018 POWER CONDUCTORS AND <br /> CABLES <br />
The URL can be used to link to this page
Your browser does not support the video tag.