Browse
Search
2019-193-E AMS - Sasser Companies ES remediation
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2019
>
2019-193-E AMS - Sasser Companies ES remediation
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2019 9:07:31 AM
Creation date
3/29/2019 9:19:27 AM
Metadata
Fields
Template:
Contract
Date
3/20/2019
Contract Starting Date
3/20/2019
Contract Ending Date
8/8/2019
Contract Document Type
Agreement - Construction
Agenda Item
3/19/19; 8-i
Amount
$1,499,409.00
Document Relationships
2019-408-E AMS - Sasser Change Request 1 drywall removal
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-480-E AMS - Sasser Companies mechanical system replacement contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-778-E AMS - Sasser Companies Inc ES remediation amendment 3
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-918-E AMS - Sasser ES Change Request 4
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2020-068-E AMS - Sasser Companies ES panel install contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2020's\2020
Agenda - 03-19-2019 8-i - Approval of a Construction Contract for the Remediation, Repair, and Reconstruction of the Phillip Nick Waters Emergency Services Building
(Attachment)
Path:
\Board of County Commissioners\BOCC Agendas\2010's\2019\Agenda - 03-19-19 Regular Meeting
R 2019-193 AMS - Sasser Companies ES remediation
(Attachment)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2019
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
557
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: B94F2D40-3B3C-47A7-86C2-6F1 B4F92C62C <br /> Orange County Emergency Services Building Construction Documents <br /> SECTION 23 07 19 <br /> HVAC PIPING INSULATION <br /> PART 1 GENERAL <br /> 1.01 SECTION INCLUDES <br /> A. Piping insulation. <br /> B. Flexible removable and reusable blanket insulation. <br /> C. Jackets and accessories. <br /> 1.02 REFERENCE STANDARDS <br /> A. ASTM B209- Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate; 2014. <br /> B. ASTM B209M - Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate (Metric); <br /> 2014. <br /> C. ASTM C534/C534M - Standard Specification for Preformed Flexible Elastomeric Cellular Thermal <br /> Insulation in Sheet and Tubular Form; 2016. <br /> D. ASTM E84- Standard Test Method for Surface Burning Characteristics of Building Materials; 2018. <br /> E. ASTM E96/E96M - Standard Test Methods for Water Vapor Transmission of Materials; 2016. <br /> F. UL 723-Standard for Test for Surface Burning Characteristics of Building Materials; Current <br /> Edition, Including All Revisions. <br /> 1.03 SUBMITTALS <br /> A. Product Data: Provide product description, thermal characteristics, list of materials and thickness <br /> for each service, and locations. <br /> B. Manufacturer's Instructions: Indicate installation procedures that ensure acceptable workmanship <br /> and installation standards will be achieved. <br /> 1.04 QUALITY ASSURANCE <br /> A. Manufacturer Qualifications: Company specializing in manufacturing the Products specified in this <br /> section with not less than three years of documented experience. <br /> B. Applicator Qualifications: Company specializing in performing the type of work specified in this <br /> section with minimum five years of experience. <br /> 1.05 DELIVERY, STORAGE, AND HANDLING <br /> A. Accept materials on site, labeled with manufacturer's identification, product density, and thickness. <br /> 1.06 FIELD CONDITIONS <br /> A. Maintain ambient conditions required by manufacturers of each product. <br /> B. Maintain temperature before, during, and after installation for minimum of 24 hours. <br /> PART 2 PRODUCTS <br /> 2.01 REGULATORY REQUIREMENTS <br /> A. Surface Burning Characteristics: Flame spread index/Smoke developed index of 25/50, maximum, <br /> when tested in accordance with ASTM E84 or UL 723. <br /> 2.02 FLEXIBLE ELASTOMERIC CELLULAR INSULATION <br /> A. Manufacturer: <br /> 1. Aeroflex USA, Inc: www.aeroflexusa.com/#sle. <br /> 2. Armacell LLC: www.armacell.us. <br /> 3. K-Flex USA LLC: www.kflexusa.com. <br /> B. Insulation: Preformed flexible elastomeric cellular rubber insulation complying with ASTM <br /> C534/C534M Grade 1; use molded tubular material wherever possible. <br /> 1. Minimum Service Temperature: Minus 40 degrees F. <br /> 2. Maximum Service Temperature: 180 degrees F. <br /> 3. Connection: Waterproof vapor barrier adhesive. <br /> C. Elastomeric Foam Adhesive: Air dried, contact adhesive, compatible with insulation. <br /> PDC Project 18102 HVAC PIPING INSULATION 23 07 19 - 1 <br /> 12/17/2018 <br />
The URL can be used to link to this page
Your browser does not support the video tag.