2019-193-E AMS - Sasser Companies ES remediation
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2019
>
2019-193-E AMS - Sasser Companies ES remediation
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2019 9:07:31 AM
Creation date
3/29/2019 9:19:27 AM
Metadata
Fields
Template:
Contract
Date
3/20/2019
Contract Starting Date
3/20/2019
Contract Ending Date
8/8/2019
Contract Document Type
Agreement - Construction
Agenda Item
3/19/19; 8-i
Amount
$1,499,409.00
Document Relationships
2019-408-E AMS - Sasser Change Request 1 drywall removal
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-480-E AMS - Sasser Companies mechanical system replacement contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-778-E AMS - Sasser Companies Inc ES remediation amendment 3
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-918-E AMS - Sasser ES Change Request 4
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2020-068-E AMS - Sasser Companies ES panel install contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2020's\2020
Agenda - 03-19-2019 8-i - Approval of a Construction Contract for the Remediation, Repair, and Reconstruction of the Phillip Nick Waters Emergency Services Building
(Attachment)
Path:
\Board of County Commissioners\BOCC Agendas\2010's\2019\Agenda - 03-19-19 Regular Meeting
R 2019-193 AMS - Sasser Companies ES remediation
(Attachment)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2019
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
557
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: B94F2D40-3B3C-47A7-86C2-6F1 B4F92C62C <br /> Orange County Emergency Services Building Construction Documents <br /> 2.03 TAGS <br /> A. Manufacturers: <br /> 1. Advanced Graphic Engraving: www.advancedgraphicengraving.com. <br /> 2. Brady Corporation: www.bradycorp.com. <br /> 3. Brimar Industries, Inc: www.pipemarker.com. <br /> 4. Kolbi Pipe Marker Co: www.kolbipipemarkers.com. <br /> 5. Seton Identification Products, a Tricor Company: www.seton.com. <br /> B. Plastic Tags: Laminated three-layer plastic with engraved black letters on light contrasting <br /> background color. Tag size minimum 1-1/2 inch diameter. <br /> C. Metal Tags: Aluminum with stamped letters; tag size minimum 1-1/2 inch diameter with smooth <br /> edges. <br /> D. Valve Tag Chart: Typewritten letter size list in anodized aluminum frame. <br /> 2.04 STENCILS <br /> A. Manufacturers: <br /> 1. Brady Corporation: www.bradycorp.com. <br /> 2. Kolbi Pipe Marker Co: www.kolbipipemarkers.com. <br /> 3. Seton Identification Products, a Tricor Company: www.seton.com. <br /> B. Stencils: With clean cut symbols and letters of following size: <br /> 1. Ductwork and Equipment: 2-1/2 inch high letters. <br /> 2.05 PIPE MARKERS <br /> A. Manufacturers: <br /> 1. Brady Corporation: www.bradycorp.com. <br /> 2. Brimar Industries, Inc: www.pipemarker.com. <br /> 3. Kolbi Pipe Marker Co: www.kolbipipemarkers.com. <br /> 4. MIFAB, Inc: www.mifab.com. <br /> 5. Seton Identification Products, a Tricor Company: www.seton.com. <br /> B. Color: Conform to ASME A13.1. <br /> C. Plastic Pipe Markers: Factory fabricated, flexible, semi- rigid plastic, preformed to fit around pipe or <br /> pipe covering; minimum information indicating flow direction arrow and identification of fluid being <br /> conveyed. <br /> D. Underground Plastic Pipe Markers: Bright colored continuously printed plastic ribbon tape, <br /> minimum 6 inches wide by 4 mil thick, manufactured for direct burial service. <br /> 2.06 CEILING TACKS <br /> A. Description: Steel with 3/4 inch diameter color coded head. <br /> B. Color code as follows: <br /> 1. HVAC Equipment: Yellow dot. <br /> 2. Fire Dampers and Smoke Dampers: Red dot. <br /> 3. Duct Smoke Detector: Red dot. <br /> 4. Heating/Cooling Valves: Black dot. <br /> PART 3 EXECUTION <br /> 3.01 PREPARATION <br /> A. Degrease and clean surfaces to receive adhesive for identification materials. <br /> 3.02 INSTALLATION <br /> A. Install nameplates with corrosive-resistant mechanical fasteners, or adhesive. Apply with sufficient <br /> adhesive to ensure permanent adhesion and seal with clear lacquer. <br /> B. Install tags with corrosion resistant chain. <br /> C. All exposed mechanical piping in mechanical rooms, boiler rooms, on and above mezzanine levels, <br /> both insulated and uninsulated, shall be either painted or color coded using 0.030" PVC jacketing <br /> by the HVAC contractor and labeled as per the following schedule: <br /> PDC Project 18102 IDENTIFICATION FOR HVAC 23 05 53- 2 <br /> 12/17/2018 PIPING AND EQUIPMENT <br />
The URL can be used to link to this page
Your browser does not support the video tag.