DocuSign Envelope ID: B94F2D40-3B3C-47A7-86C2-6F1 B4F92C62C <br /> UPDATED 04119111 SECTION 09 65 19-RESILIENT TILE FLOORING <br /> 1.6 EXTRA MATERIALS <br /> A. Furnish extra materials described below that match products installed, are packaged with protective covering for <br /> storage, and are identified with labels describing contents. <br /> 1. Furnish not less than one box for each 50 boxes or fraction thereof, of each type, color, pattern, class, wearing <br /> surface, and size of resilient tile flooring installed. <br /> 2. Furnish not less than 10 linear feet for each 500 linear feet or fraction thereof, of each type, color, pattern, and <br /> size of resilient accessory installed. <br /> 3. Deliver extra materials to Owner. <br /> PART 2 -PRODUCTS <br /> 2.1 MANUFACTURERS <br /> A. Products: Subject to compliance with requirements, provide one of the products indicated for each designation in the <br /> Resilient Tile Flooring Schedule at the end of Part 3. <br /> 2.2 RESILIENT TILE <br /> A. Vinyl Composition Floor Tile: Products complying with ASTM F 1066 and with requirements specified in the Resilient <br /> Tile Flooring Schedule. <br /> 2.3 INSTALLATION ACCESSORIES <br /> A. Trowelable Leveling and Patching Compounds: Latex-modified, portland-cement-based formulation provided or <br /> approved by flooring manufacturer for applications indicated. <br /> B. Adhesives: Water-resistant type recommended by manufacturer to suit resilient products and substrate conditions <br /> indicated. <br /> 1. For VCT#1: Use adhesives that comply with the following limits for VOC content when calculated according to <br /> 40 CFR 59, Subpart D(EPA Method 24). <br /> a. VCT Adhesives: Not more than 50 g/L. <br /> 2. For VCT#2 (ESD): Use water based resin adhesive under ESD Tile with the following limits for VOC content <br /> when calculated to 40 CFR 59, Subpart D(EPA Method 24). <br /> a. ESD Static Dissipative Tle Adhesive: Not more than 50 g/L. <br /> PART 3-EXECUTION <br /> 3.1 EXAMINATION <br /> A. Examine substrates,areas, and conditions where installation of resilient products will occur,with Installer present,for <br /> compliance with manufacturer's requirements. Verify that substrates and conditions are satisfactory for resilient <br /> product installation and comply with requirements specified. <br /> B. Concrete Subfloors: Concrete Subfloors: Test subfloors for moisture vapor emission rate recommended by <br /> manufacturer of adhesive and tile. <br /> 1. Test slabs using ASTM F-1869(MVR test using Anhydrous Calcium Chloride). <br /> 2. Verify concrete slab alkalinity is within tolerances acceptable to tile and adhesive manufacturers. <br /> 3. Submit written reports. <br /> C. Concrete Subfloors:Verify that concrete slabs comply with ASTM F 710 and the following: <br /> 1. Slab substrates are dry and free of curing compounds,sealers,hardeners,and other materials that may interfere <br /> with adhesive bond. Determine adhesion and dryness characteristics by performing bond and moisture tests <br /> recommended by flooring manufacturer. <br /> 2. Subfloor finishes comply with requirements specified in Division 03 Section "Cast-in-Place Concrete"for slabs <br /> receiving resilient flooring. <br /> 3. Subfloors are free of cracks, ridges, depressions, scale, and foreign deposits. <br /> D. Do not proceed with installation until unsatisfactory conditions have been corrected. <br /> 3.2 PREPARATION <br /> A. General: Comply with resilient product manufacturer's written installation instructions for preparing substrates <br /> indicated to receive resilient products. <br /> ©BOOMERANG DESIGN 09 65 19-2 510 Meadowlands Drive,Hillsborough,NC <br /> BD#1835 ORANGE COUNTY,NC 11/15/18 <br />