Orange County NC Website
DocuSign Envelope ID: B94F2D40-3B3C-47A7-86C2-6F1 B4F92C62C <br /> UPDATED 04119111 SECTION 09 65 19-RESILIENT TILE FLOORING <br /> SECTION 09 65 19 - RESILIENT TILE FLOORING <br /> PART 1 -GENERAL <br /> 1.1 SUMMARY <br /> A. This Section includes the following: <br /> 1. Vinyl composition floor tile. <br /> 2. Electrostatic Dissipative Vinyl composition floor tile. <br /> B. Related Sections include the following: <br /> 1. Division 09 Section "Resilient Base and Accessories" for resilient wall base, reducer strips, and other <br /> accessories installed with resilient floor tiles. <br /> 1.2 SUBMITTALS <br /> A. Samples for Initial Selection: Manufacturer's color charts consisting of units or sections of units showing the full range <br /> of colors and patterns available for each type of product indicated. <br /> B. Test Reports: Submit test reports confirming substrate moisture vapor emission rate and alkalinity are within limits <br /> acceptable to tile and adhesive manufacturers. <br /> C. Maintenance Data: For resilient floor tile to include in the maintenance manuals specified in Division 01. <br /> 1.3 QUALITY ASSURANCE <br /> A. Installer Qualifications: Engage an experienced installer to perform work of this Section who has specialized in <br /> installing resilient products similar to those required for this Project and with a record of successful in-service <br /> performance. <br /> B. Source Limitations: Obtain each type, color, and pattern of product specified from one source with resources to <br /> provide products of consistent quality in appearance and physical properties without delaying the Work. <br /> C. Fire-Test-Response Characteristics: Provide products with the following fire-test-response characteristics as <br /> determined by testing identical products per test method indicated below by a testing and inspecting agency <br /> acceptable to authorities having jurisdiction. <br /> 1. Critical Radiant Flux: 0.45 W/sq. cm or greater when tested per ASTM E 648. <br /> 2. Smoke Density: Maximum specific optical density of 450 or less when tested per ASTM E 662. <br /> 1.4 DELIVERY, STORAGE,AND HANDLING <br /> A. Deliver products to Project site in manufacturer's original, unopened cartons and containers, each bearing names of <br /> product and manufacturer, Project identification, and shipping and handling instructions. <br /> B. Store products in dry spaces protected from the weather,with ambient temperatures maintained between 50 and 90 <br /> deg F. <br /> C. Store tiles on flat surfaces. <br /> D. Move products into spaces where they will be installed at least 48 hours before installation, unless longer conditioning <br /> period is recommended in writing by manufacturer. <br /> 1.5 PROJECT CONDITIONS <br /> A. Maintain a temperature of not less than 70 deg F or more than 95 deg F in spaces to receive products for at least 48 <br /> hours before installation, during installation, and for at least 48 hours after installation, unless manufacturer's written <br /> recommendations specify longer time periods. After postinstallation period, maintain a temperature of not less than <br /> 55 deg F or more than 95 deg F. <br /> B. Do not install products until they are at the same temperature as the space where they are to be installed. <br /> C. Close spaces to traffic during flooring installation and for time period after installation recommended in writing by <br /> manufacturer. <br /> D. Install tiles and accessories after other finishing operations, including painting, have been completed. <br /> E. Where demountable partitions and other items are indicated for installation on top of resilient tile flooring, install tile <br /> before these items are installed. <br /> F. Do not install flooring over concrete slabs until slabs have cured and are sufficiently dry to bond with adhesive, as <br /> determined by ASTM F 1869, or manufacturer's recommended bond and moisture test. <br /> ©BOOMERANG DESIGN 09 65 19-1 510 Meadowlands Drive,Hillsborough,NC <br /> BD#1835 ORANGE COUNTY,NC 11/15/18 <br />