Browse
Search
2019-193-E AMS - Sasser Companies ES remediation
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2019
>
2019-193-E AMS - Sasser Companies ES remediation
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2019 9:07:31 AM
Creation date
3/29/2019 9:19:27 AM
Metadata
Fields
Template:
Contract
Date
3/20/2019
Contract Starting Date
3/20/2019
Contract Ending Date
8/8/2019
Contract Document Type
Agreement - Construction
Agenda Item
3/19/19; 8-i
Amount
$1,499,409.00
Document Relationships
2019-408-E AMS - Sasser Change Request 1 drywall removal
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-480-E AMS - Sasser Companies mechanical system replacement contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-778-E AMS - Sasser Companies Inc ES remediation amendment 3
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-918-E AMS - Sasser ES Change Request 4
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2020-068-E AMS - Sasser Companies ES panel install contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2020's\2020
Agenda - 03-19-2019 8-i - Approval of a Construction Contract for the Remediation, Repair, and Reconstruction of the Phillip Nick Waters Emergency Services Building
(Attachment)
Path:
\Board of County Commissioners\BOCC Agendas\2010's\2019\Agenda - 03-19-19 Regular Meeting
R 2019-193 AMS - Sasser Companies ES remediation
(Attachment)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2019
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
557
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: B94F2D40-3B3C-47A7-86C2-6F1 B4F92C62C <br /> SECTION 09 21 16-GYPSUM BOARD ASSEMBLIES <br /> C. Provide fire rated panels where required by hourly ratings on drawings or identified in the field as an existing rated <br /> wall. <br /> 2.3 TRIM ACCESSORIES <br /> A. Interior Trim:ASTM C 1047. <br /> 1. Material: Paper-faced galvanized steel sheet. <br /> 2. Shapes: <br /> a. Cornerbead: Use at outside corners. <br /> b. LC-Bead (J-Bead): Use at exposed panel edges. <br /> c. L-Bead: Use where indicated. <br /> d. Expansion(Control)Joint:Use where indicated and where recommended by manufacturer of gypsum panels. <br /> B. Trim: Extruded accessories of profiles and dimensions indicated. <br /> 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may <br /> be incorporated into the Work include, but are not limited to, the following: <br /> a. Fry Reglet Corp. <br /> b. Gordon, Inc. <br /> c. MM Systems Corporation. <br /> d. Pittcon Industries. <br /> 2. Aluminum: Alloy and temper with not less than the strength and durability properties of ASTM B 221, <br /> alloy 6063-T5. <br /> 3. Finish: Corrosion-resistant primer compatible with joint compound and finish materials specified. <br /> 4. Drywall Control Joint Trim: H-shaped plastic edge trim to define edge of two abutting gypsum panels at <br /> control joints. H-trim to have zip strip front face, caulk reveal per Division 07, "Joint Protection". <br /> 2.4 JOINT TREATMENT MATERIALS <br /> A. General: Comply with ASTM C 475. <br /> B. Joint Tape: <br /> 1. Interior Gypsum Wallboard: Paper. <br /> C. Joint Compound for Interior Gypsum Wallboard: For each coat use formulation that is compatible with other <br /> compounds applied on previous or for successive coats. <br /> 1. Prefilling: At open joints, rounded or beveled panel edges, and damaged surface areas, use setting-type <br /> taping compound. <br /> 2. Embedding and First Coat: For embedding tape and first coat on joints, fasteners, and trim flanges, use <br /> setting-type taping compound. <br /> a. Use setting-type compound for installing paper-faced metal trim accessories. <br /> 3. Fill Coat: For second coat, use setting-type, sandable topping compound. <br /> 4. Finish Coat: For third coat, use setting-type, sandable topping compound. <br /> 2.5 ACOUSTICAL SEALANT <br /> A. Acoustical Sealant for Exposed and Concealed Joints: Nonsag, paintable, nonstaining, latex sealant complying with <br /> ASTM C 834 that effectively reduces airborne sound transmission through perimeter joints and openings in building <br /> construction as demonstrated by testing representative assemblies according to ASTM E 90. <br /> 2.6 AUXILIARY MATERIALS <br /> A. General: Provide auxiliary materials that comply with referenced installation standards and manufacturer's written <br /> recommendations. <br /> B. Laminating Adhesive:Adhesive or joint compound recommended for directly adhering gypsum panels to continuous <br /> substrate. <br /> C. Steel Drill Screws:ASTM C 1002, unless otherwise indicated. <br /> 1. Use screws complying with ASTM C 954 for fastening panels to steel members from 0.033 to 0.112 inch thick. <br /> 2. For fastening cementitious backer units, use screws of type and size recommended by panel manufacturer. <br /> ©BOOMERANG DESIGN#1835 0921 16-2 510 Meadowlands Drive,Hillsborough, NC <br /> ORANGE COUNTY,NC 11/15/18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.