2019-193-E AMS - Sasser Companies ES remediation
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2019
>
2019-193-E AMS - Sasser Companies ES remediation
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2019 9:07:31 AM
Creation date
3/29/2019 9:19:27 AM
Metadata
Fields
Template:
Contract
Date
3/20/2019
Contract Starting Date
3/20/2019
Contract Ending Date
8/8/2019
Contract Document Type
Agreement - Construction
Agenda Item
3/19/19; 8-i
Amount
$1,499,409.00
Document Relationships
2019-408-E AMS - Sasser Change Request 1 drywall removal
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-480-E AMS - Sasser Companies mechanical system replacement contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-778-E AMS - Sasser Companies Inc ES remediation amendment 3
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-918-E AMS - Sasser ES Change Request 4
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2020-068-E AMS - Sasser Companies ES panel install contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2020's\2020
Agenda - 03-19-2019 8-i - Approval of a Construction Contract for the Remediation, Repair, and Reconstruction of the Phillip Nick Waters Emergency Services Building
(Attachment)
Path:
\Board of County Commissioners\BOCC Agendas\2010's\2019\Agenda - 03-19-19 Regular Meeting
R 2019-193 AMS - Sasser Companies ES remediation
(Attachment)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2019
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
557
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: B94F2D40-3B3C-47A7-86C2-6F1 B4F92C62C <br /> SECTION 08 41 14—SECURITY SCREENS <br /> 2.2 MATERIALS <br /> A. Main frame rails: not less than 16-gauge 1" [25.4mm] x 1" [25.4mm] seamless welded galvanized steel tubing with <br /> high strength die cast metal corners which are pneumatically inserted into the frame ends with an interference fit. <br /> B. Removable face plate: extruded from 6063-T6 aluminum alloy, .062-inch thick, .212 lbs./ft., shall be attached to the <br /> sides of the main frame using tamper resistant screws. <br /> C. Face Finish: The aluminum faceplates shall be thoroughly cleaned in a 5-step bonderizing process. An <br /> electrostatically applied thermoplastic, polyester powder coating (2.5 mil min. thickness)shall be applied and baked <br /> to a hard mar-resistant finish in one of Kane's standard colors. Coating shall meet or exceed AAMA 2603. <br /> 1. Color: Dark Bronze <br /> D. Infill Finish: The main and infill shall be thoroughly cleaned in a 5-step bonderizing process. An electrostatically <br /> applied black, thermoplastic, polyester powder coating (2.5 mil min. thickness)shall be applied and baked to a hard <br /> mar-resistant finish. Coating shall meet or exceed AAMA 2603. <br /> 1. Wire Cloth: <br /> a. Wire cloth shall be woven 10-mesh to the inch from .047 [1.19] inch diameter Type 304 stainless steel <br /> wire and double crimped. <br /> 2. Perforated Panel: 14 gauge mill galvanealed with 51%open area. <br /> 2.3 COMPONENTS <br /> A. Infill Attachment: <br /> 1. The perforated panel shall be attached to the main frame with hex-head Tek Screws. <br /> 2. Wire cloth shall be hemmed 180 degrees and retained by Hex-head Tek Screws. (for 12 mesh .028 wire cloth <br /> only) <br /> 3. Hex-head Tek screws shall penetrate the infill and main frame approximately 4" [101.6] on center. <br /> PART 3-EXECUTION <br /> 3.1 EXAMINATION <br /> A. Examine areas, with Installer present, for compliance with requirements for installation tolerances and other <br /> conditions affecting performance of storefront systems. Do not proceed with installation until unsatisfactory <br /> conditions have been corrected. <br /> 3.2 INSTALLATION <br /> A. Install in accordance with approved shop drawings and specifications as approved by the manufacturer. <br /> B. Plumb and align faces in a single plane and erect screens square and true, adequately anchored to structure. <br /> C. After completion of installation, screens shall be adjusted, in working order and cleaned. <br /> END OF SECTION 08 41 14 <br /> ©BOOMERANG DESIGN#1835 0841 14-2 510 Meadowlands Drive,Hillsborough, NC <br /> ORANGE COUNTY,NC 11/15/18 <br />