Orange County NC Website
DocuSign Envelope ID: B94F2D40-3B3C-47A7-86C2-6F1 B4F92C62C <br /> SECTION 01 21 00 -ALLOWANCES <br /> 1. Allowance No. 1: Remove and replace two hundred (200) linear feet of existing sealant and backing material at <br /> CMU masonry wall control/expansion joints. Refer to Section 07 92 00, Elastomeric Joint Sealants. <br /> 2. Allowance No. 2: Remove five hundred (500) linear feet of sealant applied to cracks in CMU and cracks in CMU <br /> masonry joints. Refer to Section 04 00 20, Preparation for Masonry Restoration. <br /> 3. Allowance No. 3: Cut-out/rout one hundred (100) linear feet of cracks in CMU blocks and install backer material <br /> and sealant. Refer to Section 04 01 20, Masonry Restoration. <br /> 4. Allowance No. 4: Cut-out/rout six hundred (600) linear feet of mortar and repoint CMU masonry joints. Refer to <br /> Section 04 01 20, Masonry Restoration. <br /> 5. Allowance No. 5: Remove and replace six (6) split-faced CMU blocks. Refer to Section 04 01 20, Masonry <br /> Restoration. <br /> 6. Allowance No. 6: Cleaning of two thousand (2,000) square feet of exterior CMU masonry surface. Refer to <br /> Section 04 01 20, Masonry Restoration. <br /> 7. Allowance No. 7: Application of water repellant to seven thousand five hundred (7,500) square feet of exterior <br /> CMU masonry surface. Refer to Section 07 19 00, Water Repellants. <br /> 8. Allowance No. 8: Surface preparation and application of primer and coating to one hundred (100)square feet of <br /> sheet metal surface. Refer to Section 09 90 00, Painting. <br /> 9. Allowance No. 9: Surface preparation and application of thirty (30) linear feet of 2-inch width pre-manufactured <br /> silicone strip at metal joints. Refer to 07 92 00, Elastomeric Joint Sealants. <br /> 10.Allowance No. 10: Surface preparation and application of forty (40) linear feet of 1" wide bond breaker tape <br /> centered over joints and apply high-performance high-build polyether-fluid-applied flashing membrane 3" <br /> wide centered over the tape and gutter joints. Refer to 07 92 00, Elastomeric Joint Sealants. <br /> 11.Allowance No. 11: Fabrication and installation of six (6) square feet of 24 gauge Kynar/Hylar based <br /> fluoropolymer coated sheet metal. Refer to 07 41 10, Metal Roof Repairs. <br /> 12.Allowance No. 12: Provide and install thirty (30) stainless steel hex head screws with stainless steel washers <br /> with neoprene gasket backing. Refer to 07 41 10, Metal Roof Repairs. <br /> 13.Allowance No. 13: Provide and install twenty (20) square feet of TPO roof walk pad. Refer to 07 54 00, TPO <br /> Single-Ply Roof Repairs. <br /> END OF SECTION 01 21 00 <br /> ©BOOMERANG DESIGN#1835 01 21 00-2 510 Meadowlands Drive,Hillsborough, NC <br /> ORANGE COUNTY,NC 12/07/2018 <br />