Browse
Search
BOA agenda 121018 - cancelled due to weather
OrangeCountyNC
>
Advisory Boards and Commissions - Active
>
Orange County Board of Adjustment
>
Agendas
>
2018
>
BOA agenda 121018 - cancelled due to weather
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2018 12:37:40 PM
Creation date
12/27/2018 12:15:19 PM
Metadata
Fields
Template:
BOCC
Date
12/10/2018
Meeting Type
Regular Meeting
Document Type
Agenda
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
399
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EC <br /> Orange County Health Department yn1Flo <br /> Environmental Health Serviceswww.co.orange.nc.uslenvhlth Septic System Report Card <br /> Acct#:H186721 PIN: 9843137930 Location Address: 4300 Camp Chestnut Ridge Rd <br /> ommes Home Mallnp Address <br /> NC United Methodist Camp 700 WATERFIELD PL,GARNER, NC 27529 <br /> Operator system Type I Inaped ion Frequency <br /> Cory Brantley Engineered System (I MO Morris Center System <br /> Osts of Ihls lnspe llon Two 6a[e e}laWnspecden <br /> 04103/2018 10:00 am 12/20/2016 <br /> System Status: ❑Compliant ® Noncompliant ❑Malfunctioning <br /> See reverse for information) ®Needs Maintenance ❑Incomplete <br /> Comments: All deliveries are below 60%except zone 1. Timers to be adjusted to deliver design dosing volume,see <br /> attached timer values in green highlight; Must clean filters frequently;remote alarms along road not <br /> active. New sand in the filter doing very good. Highest LPP lateral PVC sleeve In each subfleld painted <br /> Orange for easy Identification. <br /> 1)Develop a plan to Improve the performance of each subfleld.All deliveries are below 60%except zone 1, <br /> check for leaks In zone 1,flows 97%compared to 58%last inspection. 2)Repair electrical issue with Zone <br /> Improvements 6 solenoid valve.3]Clean out septic tank at dining hall.4)Cleanituneup the alarm at the lift station,has <br /> needed: weak sound and flash. 5)Keep filters in grease and septic tanks clean before they clog up. 6)Remove <br /> roots in the lift station tank. <br /> ins ection Details <br /> Facility: I Yes No REMARKS <br /> Type,size,&sewage flow in accordance with permit? 1 ® 1 ❑ <br /> Tanks and Risers: <br /> Risers accessible, IS ❑ I Riser e:concrete <br /> Risers structurally sound,watertight? ® ❑ <br /> No Settling,surface water diverted? ® ❑ <br /> Sanitary tee in goad condition? ® ❑ <br /> Filter free of solids, in place,and secured? ❑ ® See Attached. Filter t e:N1A <br /> Was the filter cleaned at this inspection? ® ❑ <br /> Solids level<1/3 tank capacity is solids? Capacity: I ❑ ❑ I see Attached Sheet <br /> Effluent Dosing System: <br /> Solids level acceptable, <4"? ❑ ❑ see Attached Sheet <br /> Required pumps operating&cycling properly? ® ❑ <br /> High water alarm operating properly? ❑ ® remote alarms along road do not work and alarm at lift <br /> station is weak. <br /> Vent/floats/piping/valves/disconnect in good condition? ® ❑ Did not check air-releases <br /> Control panel/electrical components in good condition? ® ❑ <br /> Ground Absorption Fields: <br /> No evidence of effluent surfacing? ® ❑ <br /> Minimal ponding in subsurface trenches? ❑ ❑ Unknown <br /> Surface water diverted,no settling along trenches? ® ❑ <br /> Line cover/vegetation adequate/maintained as needed? ® ❑ I Trees being taken out progressively. <br /> Protected from traffic,destructive uses? ® ❑ <br /> Distribution devices accessible,working properly? I ❑ ® Zane 6 has trouble with current to solenoid valve. <br /> Repair area properly preserved, maintained? ❑ ❑ <br /> Turn-upslcleanoutslvalves intact&accessible? ® ❑ <br /> System Performance:PT See Attached Sheet <br /> Design Rate: gpm at ft. Measured: "! ruin,x gpi gpm at head <br /> Date: 041031201$ Signature:_ John Davis <br /> See second page for a description of"SYSTEM STATUS". If you have any questions about this report,please contact <br /> Environmental Health Services at 919-245-2373 or email'rctavis orangecountyne.gov. Information on septic system <br /> maintenance and a list of Certified Septic installers can be found on our website. <br /> 364 <br />
The URL can be used to link to this page
Your browser does not support the video tag.